DIAGNOSTIC TEST
Incline Test
Information Display (65)
menu: Settings > Information.
Service Access Code: 65 (see
The Information Display provides the equipment usage, hardware, software, error code,
and maintenance information:
INFORMATION DISPLAY
Home softkey
Error Log softkey
ODOMETER
USAGE
SW Release P'N
Hardware Version
Console S/N
1
analog to digital converter
2
Printed circuit assembly, generally referred to as either an upper PCA or lower PCA.
Contact Precor Customer Support at support@precor.com or 800.786.8404 with
any questions.
Use controls to raise/lower incline to verify the following incline
1
angle
A/D
values:
Nominal value: 13 ±5 @ -2% incline
l
Nominal value: 37 ±5 @0% incline
l
Nominal value: 242 ±5 @ 15% incline
l
"" on
page 37)
Softkeys
Select Home to exit and return to the Home page.
Select Error Log to open the Error Log table, see
Log Display" on page 97
Information Parameters
The total number of accumulated miles (or kilometers) on
the unit.
This value is stored in the upper
the PCA is replaced the accumulated miles would start
again from "0".
The total machine usage hours (hours : min).
This value is stored in the upper PCA in the console so if
that PCA is replaced the hours of use would start again
from "0".
The operating system software part number.
Hardware version.
Console serial number.
TEST DESCRIPTION
DESCRIPTION
PCA
4 Standard Service Menus
Standard Service Menus
."Error
2
in the console so if
Page 41