IBM eServer iSeries Manual page 109

Access for windows operations console
Hide thumbs Also See for eServer iSeries:
Table of Contents

Advertisement

A6005001 and B6005001
A console resource (controller) was not found during a manual IPL.
A6005004 and B6005004
A console device was not found during a manual IPL. A twinaxial controller was found but may not be
used. This is only indicating the presence of a controller. It is not indicating the controller may be
defective.
A6005007 and B6005007
A console device was not found during a manual IPL. This reference code is also indicating the presence
of hardware that may indicate another console type other than twinaxial or Operations Console (Direct)
was found. An example would be the old async console, no longer supported. This is not indicating a
failure of that hardware or that this is the intended console.
These reference codes, as well as the attention light, will be reset when a console is detected and becomes
active. It is possible that an IPL will be necessary to attempt finding a console device again if one of these
reference codes exists for a long period of time, depending on many factors, including model, hardware
present, etc. You can force the server to try finding the console again by doing a function 21 from the
control panel, remote control panel, or virtual control panel. You can also use the 65+21 functions to
gather data or attempt recovery.
System reference code A6005008 and B6005008
Use this table if you received reference codes A6005008 or B6005008. If an IPL did not find a console and
if the console type is set to anything except a 1, the system will display code A6005008 or B6005008.
v If you are attempting to use a twinaxial console the only data relevant in this SRC is word 16. Use the
table below to determine the twinaxial failure. The first 4 characters of this word contains the last 4
characters of the original failure type. For example, if word 16 contained 50010001, the
twinaxial-related SRC code would be A6005001 and the console type is set to use a twinaxial console.
Refer to that SRC code.
v If you are attempting to use Operations Console select the appropriate section in the table below as
follows:
– Local console on a network uses words 13, 14, and 15.
– Local console directly attached to the server uses words 17, 18, and 19.
Note: If you just replaced the LAN adapter associated with Operations Console (LAN), you need to wait
at least 35 minutes for the server to find and use the new LAN adapter card. In this case, once the
server is satisfied it will start using the new adapter, the console should start and the reference
code will go away.
| |
|
| | | | |
If Word 13 value is:
| |
| |
1
|
|
|
|
|
|
|
| | | |
2
Failure
No supported HW detected
or HW detected is not
expected (for example, you
replaced the LAN IOA so
the serial number is
different)
LAN IOA failed to report
LAN
Word 14 means:
Word 15 means:
In some cases the serial
number of the expected
adapter may be shown.
103
Operations Console

Advertisement

Table of Contents
loading

Table of Contents