4. Press Enter again to confirm the deletion.
|
|
5. Using option 1 create a new service tools device ID and assign the password of your choice. If
|
you delete and create a device ID, you will also have to delete and create the connection on the
PC.
|
v If you do not have another device to sign on to the system, but do have an unused service tools device
|
|
ID, do the following on the PC:
1. Delete the current configuration as follows:
|
a. Select the configuration name (under iSeries connection).
|
b. From the Connection menu, click Delete.
|
c. Click Yes to confirm the deletion if prompted.
|
|
2. Create a new configuration and use the unused service tools device ID during the configuration.
|
3. Use one of the methods above to reset the failing service tools device ID after connecting.
v If you cannot use another service tools device or service tools device ID to sign on and you are using
|
the QCONSOLE service tools device ID, you will have to use the control panel or the remote control
|
|
panel to reset the service tools device ID password by following these steps:
1. Place the system in Manual mode. Systems without a keystick will show 01 B in the Function/Data
|
display.
|
Note: Systems with a keystick should show the mode as Manual and 01 B in the Function/Data
|
display.
|
|
2. Use the following information to help determine your progress and success of the reset:
Note: If your system uses the new double-row Function/Data display control panel, you may have
|
|
to perform a function 11 in order to display the results (D1008065). Allow at least 15 seconds
|
for the initial function 65 to complete before doing a function 11 if the display did not
respond with the D1008065.
|
The double-row display control panel presents data like this (models 270 and 8xx):
|
xxxxxxxxxxxxxxxx
|
xxxxxxxxxxxxxxxx
|
|
Each word is 8 characters but 4 words are displayed at a time for words 12 through 19. For
|
example, requesting word 12 will provide you:
|
word__12word__13
|
word__14word__15
|
|
Requesting word 13 will provide you:
|
|
word__16word__17
word__18word__19
|
|
|
The single-row display control panel and the remote control panel presents data like this:
xxxxxxxx
|
|
|
Each word is 8 characters only and displayed individually. If you want word 17, you have to
request function 17.
|
The data provided in the words can be accessed using many different methods.
|
Important: In order to know where you are in the process the following information is provided:
|
80