(17)Specifications comparison between A0J2E-E56DS and QX80+QY22
Specifications
Number of input points
Insulation method
Rated input voltage
Rated input current
Operating voltage range
Maximum number of
simultaneous input
points
ON voltage/ON current
OFF voltage/OFF current
Input resistance
Input format
OFFON
Response
time
ONOFF
Response
OFFON
time high-
speed
mode (Only
upper 8
ONOFF
points)
Common terminal
arrangement
Operation indication
Specifications
Number of output points
Insulation method
Rated load voltage
Maximum load voltage
Maximum load current
Minimum load voltage,
current
Maximum inrush current
Leakage current at OFF
Maximum voltage drop at
ON
A0J2E-E56DS input
specifications
32 points
Photocoupler
12VDC/24VDC
3mA/7mA
10.2 to 26.4VDC
(Ripple ratio within 5%)
60% (10 points/common)
simultaneously ON
9.5VDC or more/2.6mA or more
19VDC or more/3mA or more
6VDC or less/1.0mA or less
11VDC or less/1.7mA or less
Approx. 3.4k
Source input
(Input current flows in.)
1ms/5ms/10ms/20ms/70ms or
5.5ms or less (TYP.)
1ms/5ms/10ms/20ms/70ms or
6.0ms or less (TYP.)
1ms/5ms/10ms/20ms/70ms or
0.5ms or less
1ms/5ms/10ms/20ms/70ms or
1.0ms or less
16 points/common
(Common terminal: TB17, TB34)
Available (Turning ON the input
turns LED ON)
A0J2E-E56DS output
specifications
12 points
Photocoupler
100 to 240VAC, 40 to 70Hz
264VAC
0.6A/ point
0.6A/point (60% ON, 55°C)
24VAC 100mA
100VAC 10mA
240VAC 10mA
20A 10ms or less
8A 100ms or less
1.5mA (120VAC 60Hz)
3mA (240VAC 60Hz)
1.5V or less
(100 to 600mA)
1.8V or less
(100mA or less)
2.0V or less
(10 to 50mA)
: Compatible,
QX80
Compatibility
16 points
Photocoupler
24VDC
Approx. 4mA
20.4 to 28.8VDC
(Ripple ratio within 5%)
100% simultaneously ON
Approx. 5.6k
Negative common
less
(Set it with CPU parameter.)
Initial setting is 10ms.
less
(Set it with CPU parameter.)
Initial setting is 10ms.
less
(Set it with CPU parameter.)
Initial setting is 10ms.
less
(Set it with CPU parameter.)
Initial setting is 10ms.
16 points/common
(Common terminal: TB18)
ON indication (LED)
QY22
Compatibility
16 points
Photocoupler
100 to 240VAC
50/60Hz±5%
264VAC
0.6A/point, 4.8A/common
24VAC 100mA
100VAC 25mA
240VAC 25mA
20A 1 cycle or less
1.5mA or less
(During 120V 60Hz)
3mA or less
(During 240V 60Hz)
1.5V or less
*1
: Partially changed, × : Incompatible
Precautions for replacement
When seventeen or more points
are used, use two QX80s.
*2
12VDC cannot be used.
*3
Rated input current is smaller.
*2
12VDC cannot be used.
*2
12VDC cannot be used.
*2
12VDC cannot be used.
*3
Input resistance is greater.
The name is different, but the
specificaton is equal.
Set the input response time of the
parameter to 5ms before use.
Set the input response time of the
parameter to 1ms before use.
Precautions for replacement
When seventeen or more points
are used, use two QY22s.
The minimum load current is
greater. Use caution on selecting
the load to use.
3
- 58

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec q series

Table of Contents