Mitsubishi Electric MELSEC-A0J2H Series Handbook page 186

Table of Contents

Advertisement

10
REPLACING THE SPECIAL FUNCTION MODULE
Item
Upper/lower
limit signals
START signal
Manual pulse
generator
A/B phase
I/O signal
Drive module
for external
ready
devices
Stop signal
Proximity
signal
Zero point
signal
Forward/
reverse field
pulse
Error value
counter clear
Signal logic
selection
Peripheral
device
connections
Peripheral
device
Teaching
(data
module
setting,
etc.)
Software
package
SW1IVD-AD71P (for IBM-PC/AT-compatible
10
- 23
A0J2-D71
None
Available
On each axis
Operating voltage range
4.75 to 26.4VDC
Operating voltage range
4.75 to 26.4VDC
Pulse width: 50µs or more
Available
Available
None
Direct connection
AD71TU
SW0GP-AD71P (for A6GPP/A6PHP)
SW1RX-AD71P (for A7PHP/A7HGP)
personal computer)
: Compatible,
QD75P2
Available
None
Only one pulse generator can be connected.
Operating voltage range
19.2 to 26.4VDC
Operating voltage range
4.5 to 6.1VDC
or
12 to 26.4VDC
Pulse width: 1 ms or more
Available
Available
Available
Programmable controller CPU, Q-compatible
serial communication module, Q-compatible
MELSECNET/H
Connection via remote I/O module
None
GX Works2
GX Configurator-QP
: Partially changed, × : Incompatible
Compat-
Precautions for
ibility
replacement
QD75P2 requires
wiring.
QD75P2 does not
have this signal. To
×
use this signal, output
it from the output
module.
At the QD75P2, the
manual pulse
generator can only be
connected to one
terminal.
Configure the buffer
memory settings to
specify the controlled
system axis.
Input specifications
are different so check
the specifications of
the connecting
device.
Connection system is
different.
The teaching module
×
cannot be used.
The usable software
package are different.