The information is described as follows:
•
Time Interval – Select the desired setting between 1s and 60s, where "s" stands for seconds.
The default value is one second.
•
Record Number – Select number of times the switch will be polled between 20 and 200. The
default value is 20.
•
LateColl – Counts the number of times that a collision is detected later than 512 bit-times into
the transmission of a packet.
•
ExColl – Counts the number of frames that experienced 16 collisions during transmission and
were aborted.
•
SingColl – Counts the number of frames transmitted that experienced exactly one collision
during transmission.
•
Coll – Counts the number of collisions experienced during the transmission of a frame as
defined as the simultaneous presence of signals on the DO and RD circuits, i.e. transmitting
and receiving at the same time.
•
Show/Hide – Check whether or not to display ExDefer, LateColl, ExColl, SingColl, and Coll
errors.
•
Clear – Clicking this button clears all statistics counters on this window.
•
View Table – Clicking this button instructs the switch to display a table rather than a line
graph.
•
View Line Chart – Clicking this button instructs the switch to display a line graph rather than a
table.
Figure 7-36. Packet Analysis window (Table)
112
DGS-3224TG Gigabit Ethernet Switch User's Guide