Configuring The Touchpanel - Crestron Isys TPS-3000L Operation Manual

6.4 inch lectern/wall mounted touchpanel
Hide thumbs Also See for Isys TPS-3000L:
Table of Contents

Advertisement

Crestron Isys™ TPS-3000L
Operations Guide – DOC. 6077
6.4" Lectern/Wall Mounted Touchpanel
Remove the Ribbon Cable
6. Rotate the pushbutton circuit board 180º and slide the ribbon cable into the
open connector (labeled J2). Insert the cable with the leads facing away
from the pushbutton circuit board.
7. Secure the ribbon cable by gently sliding the tension clip toward the
connector body.
8. Turn over the circuit board in its new orientation and install the two
pushbutton circuit board screws to finger-tight. Using a #1 Phillips
screwdriver, tighten each screw an additional 1/8-turn.
9. While holding a finger gently on the touchscreen, connect the power cable
to the NET connector on the touchpanel. This will place the touchpanel in
the setup mode.
10. Set the screen to inverted operation. Refer to "Screen Settings" on page 15
for instructions.
11. Rotate the touchpanel so the pushbuttons are located on the right side of the
touchpanel. If custom engraved button caps exist, install them to match
programming.
12. With the faceplate buttons on the right, place the supplied Crestron label on
the faceplate over the molded Crestron logo (which is now upside down).
13. The touchpanel is now ready for installation in a lectern. Refer to
"Touchpanel Mounting" on page 21 for mounting instructions.
NOTE: The sequence of digital join numbers is (top to bottom) 1 through 5 whether
the touchpanel is mounted with the buttons on the left side or right side.

Configuring the Touchpanel

NOTE: The only connection required to configure the touchpanel is power. Refer to
"Hardware Hookup" on page 17 for details.
6.4 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-3000L • 11

Advertisement