6.4" Lectern/Wall Mounted Touchpanel
28 • 6.4 Inch Lectern/Wall Mount Touchpanel: Crestron Isys™ TPS-3000L
selects the signal types by clicking on the appropriate button at the top of the Symbol
Detail view when programming the panel.
The following tables list and give functional descriptions for the touchpanel outputs
and inputs.
Digital Output Signal Descriptions
OUTPUT
press 1 through press 4000
Digital Input Signal Descriptions
INPUT
fb 1 through fb 4000
Analog Output Signal Descriptions
OUTPUT
an_act 1 through an_act 4000
Analog Input Signal Descriptions
INPUT
an_fb 1 through an_fb 4000
Serial Input Signal Descriptions
INPUT
text-01 through text-999
Device Extenders
Device extenders provide additional logic and functionality to a device. The Poll
Manager and Sleep/Wake Manager symbols are device extenders for touchpanels.
Poll Manager takes the touchpanel on and off line during polling by the control
system. Sleep/Wake Manager suspends and restores operation of the touchpanel. For
additional information about Device Extenders, refer to the latest version of the
Crestron SIMPL Windows Symbol Guide (Doc. 6120), or the on-line help included
with SIMPL Windows.
Example Program
An example program for the TPS-3000L is available from the Crestron FTP site
(ftp://ftp.crestron.com/Examples). Search for the file TPS3000L.ZIP that contains
the example program, associated files and a README.TXT file that describes the
program.
Programming with VisionTools™ Pro-e
VT Pro-e, a design and programming Windows
creation of unlimited control screen variations incorporating two and three-
dimensional graphics and text as well as video and sounds (recorded as WAV files).
A set of pages, which make up a project, can be designed for each TPS-3000L
touchpanel application. Each page contains objects such as custom control graphics,
Crestron Isys™ TPS-3000L
DESCRIPTION
Notifies control system of button press (1 - 4000).
High/1 = Button being pressed
Low/0 = Button not being pressed
DESCRIPTION
Notifies panel of button press (1 - 4000). This can
represent that the button was pressed, or can be
an actual device feedback, e.g., that power was
turned on.
DESCRIPTION
Notifies control system of an action (1 - 4000). Any
value from 0 through 65535
DESCRIPTION
Notifies panel of analog action (1 - 4000).
DESCRIPTION
Notifies panel of text string (1 - 999). Also called
indirect text.
®
-based software, permits the
Operations Guide – DOC. 6077