Connecting The Electrical Connection Line - Henny Penny FlexFusion FPE-615 Installation Manual

Electric platinum combi incl. grease collection
Hide thumbs Also See for FlexFusion FPE-615:
Table of Contents

Advertisement

Prerequisite Unit dead

6.2.2 Connecting the electrical connection line

DANGER
DANGER
A
T1
Image: A Transformer T1 location; B Transformer connections for control system
Left side wall removed
1. Use an appropriate meter to measure the supply voltage.
The voltage range must match the information on the
nameplate.
If voltage fluctuations are to be expected, take the maximum
expected voltage into account.
2. Check whether the transformer voltage is within the specified
range (see "Unit and connection data").
If the set voltage differs, reposition the connections for the
transformer voltage.
Document the new voltage that was set on the sticker.
3. In units with several transformer, repeat the procedure for each
transformer.
4. Close the housing (see "Opening and closing the housing").
5. Fill out the Start-up operation report.
Risk of personal injury and property damage from electric shock
• Before working on the unit, ensure that the unit is dead.
• Do not operate the unit with the housing open.
Risk of personal injury and property damage from electric shock
• Before connecting, ensure that the electrical connection line is dead.
• Ensure that the electrical connection line is undamaged.
Installation instructions
Connecting the unit
B
X1
X2
31

Advertisement

Table of Contents
loading

Table of Contents