Connecting the unit

6.2.2 Description of the electrical connection

6.2.3 Connecting the electrical connection line

DANGER
DANGER
26
Image: Electrical connection terminal diagram in the unit
A, B, C, D Power optimization
system
13, 14 Potential-free contact
L1, L2, L3 Line conductors
N Neutral conductor
Risk of personal injury and property damage from electric shock
• Before working on the unit, ensure that the unit has been disconnected from
the power supply.
Risk of personal injury and property damage from electric shock
• Before connecting, ensure that the electrical connection line is dead.
• Ensure that the electrical connection line is undamaged.
Installation instructions
X2
PE Protective conductor
X1 Connection to electrical
X2 Power optimization system
X1
outlet
connection (POS)