Code 1
Code 2
A0
14
Decoding error continued for 15 seconds or more.
A0
15
Time-out: 13 seconds or more for one-line transmission.
A0
16
RTC not found or carrier OFF detected for 6 seconds.
A0
17
RTC found but no command detected for 60 seconds or
longer.
A0
19
No video data to be sent.
A0
20
Cannot continue receiving color fax (remaining ink low).
A8
01
RTN, PIN, or ERR received (sending terminal).
A9
01
RTN, PIN, or ERR sent (receiving terminal).
AA
18
Receive buffer full during receiving data into memory.
B0
01
Polarity reversion detected.
B0
02
Unable to receive the next-page data.
B0
03
Unable to receive polling during turn-around transmission
due to call reservation.
B0
04
PC interface error
C0
01
No common modulation mode or failed to poll.
C0
02
Unable to detect JM.
C0
03
Unable to detect CM.
C0
04
Unable to detect CJ.
C0
10
Cannot finish V. 34 negotiation or training.
C0
11
Modem error detected during V. 34 negotiation or training.
C0
20
Modem error detected while sending commands.
C0
21
Modem error detected while receiving commands.
C0
22
Control channel connection time-out.
C0
30
Modem error detected while sending video signals.
C0
31
Modem error detected while receiving video signals.
E0
01
Failed to detect 1,300 Hz signal in burn-in operation.
E0
02
Failed to detect PB signals in burn-in operation.
E0
03
Unable to detect commands in burn-in operation when
RS232C is used.
Cause
2-61
Refer to:
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.4
4.13.2
4.13.2
4.13.2
4.13.2
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
4.13.3
Confidential