9.15 Modem flat cable / Modem PCB

(1) Disconnect the Modem flat cable from the Main PCB, and release it from the securing fixtures.
Harness routing: Refer to
(2) Remove the two Screw cup M3x8 (black) screws to remove the Modem ground wire L/R
from the Modem plate.
(3) Remove the two Taptite bind B M4x12 screws to remove the Modem plate from the Joint
cover ASSY. Disconnect the Modem flat cable from the Modem PCB.
(4) Remove the Screw cup M3x8 (black) screw to remove the Modem shield cover from the Modem plate.
(5) Remove the three Screw cup M3x8 (black) screws to remove the Modem PCB from the
Modem plate.
Screw cup M3x8 (black)
Taptite bind B M4x12
Screw cup M3x8 (black)
Modem flat cable
Screw cup M3x8 (black)
Modem ground wire L
Joint cover ASSY
Fig. 3-52