Brother HLL3290CDW Service Manual page 185

Hide thumbs Also See for HLL3290CDW:
Table of Contents

Advertisement

Completely blank
<User Check>
Step
Incorrect white level
1
correction data
First or second side CIS flat
2
cable failure
First or second side CIS unit
3
failure
4
Main PCB failure
All black
<User Check>
Step
Incorrect white level
1
correction data
First or second side CIS flat
2
cable failure
First or second side CIS unit
3
failure
4
Main PCB failure
• Check that the document is not reversed.
Cause
• Install all the latest firmwares.
Cause
2-149
Remedy
Execute "Acquire white level data
code
55)".
Replace the first or second side CIS flat
cable.
Replace the first or second side CIS unit.
Replace the main PCB.
Remedy
Execute "Acquire white level data
code
55)".
Replace the first or second side CIS flat
cable.
Replace the first or second side CIS unit.
Replace the main PCB.
(Function
(Function
Confidential