(5) Remove each Hook, and turn the MP separation pad ASSY upright to remove it upward.
(6) Remove the MP separation pad spring from each Pin.
MP separation pad ASSY
MP separation pad spring
Hooks
Pins
Fig. 7-17
(7) After replacing the PF kit MP, reset the counter.
(Refer to
"1.3.36 Reset counters for consumable parts (Function code 88)" in Chapter
5.)