8.
DRAWER KICK-OUT CONNECTOR, POWER CONNECTOR
8.1
Drawer Kick-Out Connector
8.1.1
Specifications of Drawer Kick-Out Connector
(1) Drawer kick-out drive signal
Outputs a pulse specified with ESC p.
interface connector, or with the DLE EOT, GS a, and GS r commands through the serial/parallel interface.
(2) Electrical characteristics
1) Drive voltage: 24 V DC
2) Drive current: 0.8 A at maximum (Within 510 ms)
3) Switch signal level: "L" = 0 to 0.5 V,
8.1.2
Connector's Pin Configuration
No.
1
2
DRAWER 1
3
DRSW
4
5
DRAWER 2
6
CAUTION
8.1.3
Drive Circuit
Signal
FG
Frame Ground
Drawer 1 drive signal
Drawer switch input
VDR
Drawer drive power
Drawer 2 drive signal
GND
Common ground on the circuit
Connector used
Applicable connector
: • No output is made while printing.
• The drawers 1 and 2 cannot be driven simultaneously.
• A solenoid used for the drawer should be of 36
be kept below 0.8 A. Use beyond this limit cannot be assured.
• This connector cannot be connected to a telephone line.
the solenoid.
The status of SW (+) can be checked with pin 34 on the parallel
"H" = 3 to 5 V
Function
: TM5RJ3-66 (Hirose) or its equivalent
: TM3P-66P (Hirose) or its equivalent
33
iDP3221 User's Manual
or more. An output current should
Do not connect other than
CITIZEN