Citizen iDP-3221 Series User Manual page 77

Line thermal printer
Hide thumbs Also See for iDP-3221 Series:
Table of Contents

Advertisement

ESC
D
[ n ]
[Function]
Setting horizontal tab position
[Code]
<1B> H <44> H [<n>] k <00> H
[Range]
1 n 255
0 k 32
[Outline]
Specifying a horizontal tab position.
• "n" indicates the number of columns from the beginning to the horizontal tab position.
this time, "n= set position 1" is to be specified.
column, n=8 is to be specified.
• "k" denotes the number of horizontal tab positions you want to set.
• The tab position is set at position where it is "character width n" from the line beginning.
The character width, at this time, includes the rightward space amount.
characters, it is made double of the ordinary case.
• Tab positions can be specified are maximum 32.
• <n> k, which denotes a setting position, is input in the increasing order and ends at <00> H.
• ESC D NUL clears all the set tab positions.
is ignored.
[Caution]
When the data, <n> k, is equal to or smaller than its preceding data, <n> k-1, it is assumed
that tab setting is finished.
normal data.
When the data, <n> k, exceeds a 1-line print area, set the horizontal tab position, assuming
"Set digit position = Maximum print digits + 1."
change even if the character width is altered after setting the horizontal tab position.
[Default]
• Initial value is specified for each eight characters (9th., 17th., 25th. columns) of Font A.
[See Also]
HT
[Sample Program]
See Sample Program and Print Results for HT on page 40.
k
NUL
If this is the case, the next data onward will be processed as
For example, to set the position at 9th
Specifying exceeding this is ignored.
Following clearing, horizontal tab command
The horizontal tab position does not
[Print Results]
61
iDP3221 User's Manual
At
In double wide
CITIZEN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idp3221rfIdp3221pf

Table of Contents