Bosch Video Management System
Close Operator Client
Select the check box to allow closing the Operator Client.
Minimize Operator Client
Select the check box to allow minimizing the Operator Client.
Audio Intercom
Select the check box to allow the user to speak on the loudspeakers of an encoder with audio-
in and audio-out function.
Manual Alarm Recording
Select the check box to allow manual alarm recording.
If you clear this check box, the Metadata permissions for all available cameras on the Camera
Permissions page are cleared and disabled.
Access VRM Monitor
Select the check box to allow access to the VRM Monitor software.
Set reference image
Select the check box to allow updating the reference image in the Operator Client.
Set Area Selection for Reference Image
Select the check box to allow selecting the area in the camera image for updating the
reference image in the Operator Client.
Limit access to recorded video to the last n hours.
Select the check box to limit the access to recorded videos.
In the list, enter the number of hours.
24.10
Priorities page
Main window >
Allows you to configure the timeout for explicit PTZ locking. You can set the priorities for PTZ
control and the display of incoming alarms.
Control Priorities
Move the appropriate slider to the right to decrease the priority for acquiring PTZ controls and
Bosch Allegiant trunk lines. A user with a high priority can lock the PTZ controls or the control
of a trunk line for users with lower priorities. You set the timeout for locking PTZ control on
the Timeout in min. field. The default setting is 1 minute.
Automatic Popup Behavior
Move the slider to adjust the priority value of Live Image window or Playback Image window.
This value is required for incoming alarms to decide whether this alarm is automatically
displayed in the Alarm Image window.
For example: If you move the slider for Live Image window to 50 and for the Playback Display
to 70 and an alarm comes in with a priority of 60, the alarm is only automatically displayed if
the user has Playback Display active. The alarm is not automatically displayed when the user
has Live Display active.
Timeout in min.
Enter the time period in minutes.
Bosch Sicherheitssysteme GmbH
User Groups >
> Priorities tab
Configuration Manual
User Groups page | en 153
Configuration Client | V3 | 2010.07