System Delay Example - Semi-Auto Mode/Skip Line - Graco TapeLazer HP Automatic Operation, Parts

Table of Contents

Advertisement

Operation

System Delay Example - Semi-Auto Mode/Skip Line

[S] Semi-Auto Mode Skip Line placement using
SD example shown: 1 ft intermittent skip, 72 inch
System Delay.
Tape Application Button Activity
Press and RELEASE auto tape application button
when pointer [A] reaches the beginning of each line
[B]. Each button press produces only one line at the
programmed length (1 foot in this example).
Repeat for all intermittent lines.
If the button is pressed before the end of the
programmed length [C], that line will end at that
point, except:
if the pointer is less than 1 foot from the start of the
line [B], the button press will be ignored, with a
message on the screen. The operator will need to
travel further before pressing the button to end the
line.
NOTE: The minimum achievable space between
intermittent lines is approximately 1 ft. If the button
press to start a new line is less than one foot from
the end of the previous line that button press will be
ignored. The operator will need to travel further
before pressing the button to start a new line.
Tape Interrupt
All system delay operation can be canceled by:
turning System Delay OFF, turning the LINE TYPE
button off (both LEDs off), or double pressing the
tape application button.