• FUNC 28
Bit
7
Transmission attenuator value for V.34 modem:
6
Counted up in the range from 0000 to 1111, in units of -1 dB.
5
0000 to 1111 ...
4
0000: 0 dB
0001: -1 dB
0010: -2 dB
.
1001: -9 dB
.
1111: -15 dB
3
Undefined
2
1
0
<Remarks>
FUNC 28 Bits 7 to 4:
The bit settings allow the user to program the modem transmission attenuation level. The smaller the
set value, the higher the transmission level becomes. If errors occur frequently or training is not sent,
the transmission level should be changed, as a rule.