1.3 Remote Service

1.3.1 RDC (Remote Diagnosis Configuration) Service
(1) Remote Access
The remote access function allows checking of the copier conditions, and enabling the function for chang-
ing setting data of the copier and the firmware that controls the copier, on a remote basis, via communica-
tion.
To enable the remote access function, be sure to follow the setting procedure described below.
<Key used in operation>
PROGRAM
Select DEFAULT SETTINGS
SET
Select REMOTE SERVICE
SET
Select REMOTE ACCESS
SET
Select ON
SET
Note: When OFF is selected for Remote Access, accesses through RDC cannot be made. Requests for
uploading and downloading the phonebook, retrieving the list, downloading programs, and auto-
matic accesses, over the line, are rejected. However, this setting does not have influence on
accesses through LDC or the network.
GD-1060 ADJUSTMENT ITEMS
Press the PROGRAM Key
Use
and
keys
Use
and
keys
1 - 104
<Display messages>
PROGRAM
01.DEFAULT SETTINGS
02.LISTS
03.INITIAL SETUP
DEFAULT SETTINGS
05.E-MAIL SETUP
06.REPORTS & LIST
07.REMOTE SERVICE
REMOTE SERVICE
01.REMOTE ACCESS
02.DOWNLOAD FIRMWARE
03.RDC PASSWORD
REMOTE ACCESS
1.OFF
2.ON