5.5.

Brine dosage

Set the brine dosage.
A
Press
until desired brine dosage appears then release.
→ Range from 0.2 kg to 6.0 kg;
from 0.2 kg to 1.0 kg by increments of 0.05 kg;
from 1.0 kg to 3.0 kg by increments of 0.1 kg;
from 3.0 kg to 6.0 kg by increments of 0.5 kg.
5.6.

Volumetric regeneration

3
Set the capacity in [m
A
Press
until desired capacity appears then release.
→ Range from 0.4 to 9.5 m
3
from 0.4 m
to 1.0 m
(12 increments);
3
from 1.0 m
to 3.0 m
(20 increments);
3
from 3.0 m
to 5.0 m
(10 increments);
3
from 5.0 m
to 9.5 m
(10 increments).
5.7.

Time clock regeneration (Riversoft 4 only)

Set the time between each regeneration.
A
Press
until desired interval appears then release.
→ Range from 0 through 30;
0 = Disabled;
0.3 = Regeneration every 8 hours: at 2, 10 and 18 hours;
0.5 = Regeneration every 12 hours: at 2 and 14 hours;
1 - 30 = Regeneration every X days (every 3 days in this
example).
Ref. MKT-IM-045 / A - 13.03.2020
] between each regeneration.
3
;
3
by increments of 0.05 m
3
by increments of 0.1 m
3
by increments of 0.2 m
3
by increments of 0.5 m
Installer Manual Riversoft - Programming
3
3
3
3
47 / 90