Quick program guide

Parameter
Range of values
description

Time of day

Brine dosage
Volumetric
regeneration
Calendar override
System selection
5.4.
Time of day
Set the current time.
A
Press
until desired hour appears then release.
→ Range from 0 through 23 hours.
→ The elapsed minutes will reset to zero when the hours are
changed.
46 / 90
Default
value
0:00 - 23:59
12:00
0.2 - 6.0
0.6
0.4 - 9.5
3.6
0 - 30
3
1 - 4
1
Units of
measure
hour:
minute
From 0.2 kg to 1.0 kg by increments
of 0.05 kg;
from 1.0 kg to 3.0 kg by increments of
kg
0.1 kg;
from 3.0 kg to 6.0 kg by increments of
0.5 kg.
From 0.4 m
3
of 0.05 m
;
from 1.0 m
3
of 0.1 m
;
3
m
from 3.0 m
3
of 0.2 m
;
from 5.0 m
3
of 0.5 m
.
0 = Disabled;
0.3 = Regeneration every 8 hours: at
2, 10 and 18 hours;
day
0.5 = Regeneration every 12 hours: at
2 and 14 hours;
1 - 30 = Regeneration every X days.
See 5.10. Regeneration cycles time,
-
page 48.