Pentair FLECK 5600 SXT Installer Manual
Hide thumbs Also See for FLECK 5600 SXT:
Table of Contents

Advertisement

FLECK
5600 SXT

Advertisement

Table of Contents
loading

Summary of Contents for Pentair FLECK 5600 SXT

  • Page 1 FLECK 5600 SXT...
  • Page 2: Table Of Contents

    Installer Manual Fleck 5600 - SXT - Table of content Table of content Generalities ......... . 7 1.1.
  • Page 3 Installer Manual Fleck 5600 - SXT - Table of content System sizing ........25 4.1.
  • Page 4 Installer Manual Fleck 5600 - SXT - Table of content Programming ........47 6.1.
  • Page 5 Installer Manual Fleck 5600 - SXT - Table of content Commissioning ........61 7.1.
  • Page 6 Installer Manual Fleck 5600 - SXT - Table of content Spare parts ......... 81 11.1.
  • Page 7: Generalities

    Author Description 21.12.2016 First edition 1.3. Manufacturer identifier, product Manufacturer: Pentair Manufacturing Italy Srl Via Masaccio, 13 56010 Lugnano di Vicopisano (PI) – Italy Product: Fleck 5600 - SXT 1.4. Intended use The device is intended to be used for domestic applications only and it is purpose-built for water treatment.
  • Page 8: Abbreviations Used

    Installer Manual Fleck 5600 - SXT - Generalities 1.5. Abbreviations used DF............Down Flow UF............Up Flow HW............Hot Water Inj ............Injector DLFC ............Drain Line Flow Controller BLFC / Refill Flow Controller....Brine Line Flow Controller QC............Quick Connect Regen ............
  • Page 9: Procedure For Technical Support

    Pentair Quality System EMEA products benefit, under specific conditions, from a manufacturer warranty that may be invoked by Pentair’s direct customers. Users should contact the vendor of this product for applicable conditions and in case of a potential warranty claim.
  • Page 10: Safety

    Installer Manual Fleck 5600 - SXT - Safety Safety 2.1. Safety pictograms definition Caution Warning Warns of a risk of minor injury or major Warns against serious personal injury material damage to the device or and damage to health. environment. Danger...
  • Page 11: Personnel

    Installer Manual Fleck 5600 - SXT - Safety 2.3.1. Personnel Only qualified and professional personnel, based on their training, experience and instruction as well as their knowledge of the regulations, the safety rules and operations performed, are authorized to carry out necessary work. 2.3.2.
  • Page 12: Description

    Installer Manual Fleck 5600 - SXT - Description Description 3.1. Technical specifications Design specifications/ratings Valve body ..........Fiber-reinforced polymer Rubber components ....... EP or EPDM Valve material certification ....DM174, ACS, CE Weight (valve with controller) ....2 kg (max) Recommended operating pressure ..
  • Page 13: Performance Flow Rate Characteristics

    Installer Manual Fleck 5600 - SXT - Description Environmental conditions • Indoor use only; • Temperature from 5°C to 40°C; • Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C; • Mains supply voltage fluctuations up to ±10% of the nominal voltage. 3.1.1.
  • Page 14: Outline Drawing

    Installer Manual Fleck 5600 - SXT - Description 3.2. Outline drawing 14 / 92 Ref. MKT-IM-013 / A - 21.12.2016...
  • Page 15: Description And Components Location

    Installer Manual Fleck 5600 - SXT - Description 3.3. Description and components location Controller LCD screen Drive cam Regen button Brine line Up button Injector block Down button *Meter Drain line Mixing device Inlet Outlet Brine cam Motor Brine valve Piston *Not included in case of timeclock Ref.
  • Page 16: System Regeneration Cycle

    Installer Manual Fleck 5600 - SXT - Description 3.4. System regeneration cycle Note This valve allows to do down flow or up flow regenerations. 3.4.1. Down flow regeneration cycle (5-cycles operation) Service — normal use Untreated water is directed down through the resin bed and up through the riser tube. The hardness ions attach themselves to the resin and are removed from the raw water being exchanged on the resin beads against sodium ions.
  • Page 17 Installer Manual Fleck 5600 - SXT - Description Note For illustration purpose only. Always verify inlet and outlet marking on the valve. SERVICE NORMAL USE BACKWASH Outlet Inlet Outlet Inlet Drain Valve Valve BRINE DRAW & SLOW RINSE SECOND BACKWASH (Double backwash units only) Outlet Inlet...
  • Page 18: Up Flow Regeneration Cycle (5-Cycles Operation)

    Installer Manual Fleck 5600 - SXT - Description 3.4.2. Up flow regeneration cycle (5-cycles operation) Service — normal use Untreated water is directed down through the resin bed and up through the riser tube. The hardness ions attach themselves to the resin and are removed from the raw water being exchanged on the resin beads against sodium ions.
  • Page 19 Installer Manual Fleck 5600 - SXT - Description Note For illustration purpose only. Always check for inlet and outlet marking on the valve. SERVICE NORMAL USE BRINE DRAW & SLOW RINSE Outlet Inlet Outlet Inlet Drain Valve Valve From brine tank BACKWASH RAPID RINSE...
  • Page 20: Filter Cycle (3-Cycles Operation)

    Installer Manual Fleck 5600 - SXT - Description 3.4.3. Filter cycle (3-cycles operation) Service — normal use Untreated water is directed down through the media and up through the riser tube. The impurities are retained by the media. The water is filtered as it passes through the media. Backwash —...
  • Page 21: Configurations For Downflow Softener, Upflow Softener And Filter

    Installer Manual Fleck 5600 - SXT - Description 3.5. Configurations for downflow softener, upflow softener and filter To configure the valve as downflow softener, upflow softener or filter, the valve body, the piston and the cycle cam must be set as shown below. Caution...
  • Page 22: Upflow Softener

    Installer Manual Fleck 5600 - SXT - Description 3.5.2. Upflow softener Upflow piston P/N 25593 Upflow valve body with mixing P/N 28405-40 Red drive cam P/N 17885 22 / 92 Ref. MKT-IM-013 / A - 21.12.2016...
  • Page 23: Filter

    Installer Manual Fleck 5600 - SXT - Description 3.5.3. Filter Downflow piston P/N 27077 Plugged BLFC and injector Downflow valve body without mixing P/N 28405-10 Black single backwash drive cam P/N 17438 Ref. MKT-IM-013 / A - 21.12.2016 23 / 92...
  • Page 24: Options Available On The Valve

    Installer Manual Fleck 5600 - SXT - Description 3.6. Options available on the valve Mixing device The valve can be equipped with a mixing device (1) whose function is to regulate the hardness of the water at the outlet. The mixing can be set from 0% to 50% of hard water (i.e. 0 turn = 0% of hard water with 100% of treated water and 1-½...
  • Page 25: System Sizing

    Installer Manual Fleck 5600 - SXT - System sizing System sizing 4.1. Recommendations 4.1.1. Injector/DLFC/BLFC-Valve configuration Resin Diameter Injector DLFC BLFC Valve volume type [in] Color Color [gpm] DF [gpm] UF [gpm] 0000 Black 0.125 5 - 8 Brown 0.125 9 - 14 Violet 15 - 21...
  • Page 26 Installer Manual Fleck 5600 - SXT - System sizing The softening and regeneration reactions are driven under certain conditions. To allow these reactions to take place, make sure that the velocity is convenient during the different phases for proper ion exchange. This velocity is given in the resin manufacturer specifications sheet. Depending on the inlet water hardness, the service velocity for standard softening must be between: Inlet water hardness Service velocity...
  • Page 27: Determining The Required Volume Of Resin

    Installer Manual Fleck 5600 - SXT - System sizing 4.2.2. Determining the required volume of resin When sizing a softener, make sure that the volume of resin in the tank (bed volume) will be sufficient so that even when the peak flow rate is reached, the velocity is still between the above values depending on the hardness.
  • Page 28 Installer Manual Fleck 5600 - SXT - System sizing Resin exchange capacity as a function of the salt dosage: Salt amount Corresponding resin exchange °f.m °dH.m [g/L capacity in [g/L ] as CaCO [per L [per L resin resin resin resin 29.9 2.99...
  • Page 29: Valve Configuration

    Installer Manual Fleck 5600 - SXT - System sizing To calculate the system volume capacity: / TH with: capacity capacity inlet : system volume capacity [m capacity : system mass capacity [kg as CaCO ] or [°f.m or °dH.m capacity : system combined capacity [°f.m or °dH.m capacity...
  • Page 30: Cycle Time Calculation

    Installer Manual Fleck 5600 - SXT - System sizing Note This value does not correspond to the brine draw flow rate but to the total flow rate passing through the injector. Then refer to the injector diagrams for the chosen tank size and at the inlet pressure in order to check if the injector will give a correct flow rate.
  • Page 31 Installer Manual Fleck 5600 - SXT - System sizing Note Multiply the amount of salt in kg by 3 to get a approximation of the brine volume to draw. To calculate slow rinse duration: The volume of water to be used for slow rinse is given in the resin manufacturers specifications. Generally speaking, it is advised that between 2 and 4 BV of water is used to perform the slow rinse after brine draw.
  • Page 32: Salt Amount Definition

    Installer Manual Fleck 5600 - SXT - System sizing 4.3. Salt amount definition The salt setting is done through the controller programming. 4.4. 1650 Injector flow rates The following tables and graphics represent the injectors flow rate as a function of the inlet pressure for the different injector sizes.
  • Page 33 Installer Manual Fleck 5600 - SXT - System sizing INJECTOR 0 Total Rinse Draw Inlet pressure [bar] INJECTOR 1 Total Rinse Draw Inlet pressure [bar] INJECTOR 2 Total Rinse Draw Inlet pressure [bar] Ref. MKT-IM-013 / A - 21.12.2016 33 / 92...
  • Page 34 Installer Manual Fleck 5600 - SXT - System sizing INJECTOR 3 Total Rinse Draw Inlet pressure [bar] INJECTOR 4 Total Rinse Draw Inlet pressure [bar] INJECTOR 5 Total Rinse Draw Inlet pressure [bar] 34 / 92 Ref. MKT-IM-013 / A - 21.12.2016...
  • Page 35: Installation

    Installer Manual Fleck 5600 - SXT - Installation Installation Mandatory It is strictly forbidden for not qualified personal, to accede to system’s internal parts to perform any kind of technical action. Be sure to disconnect the electrical power, close the water inlet and depressurize the system before opening the front cover to access internal parts.
  • Page 36: Water

    Installer Manual Fleck 5600 - SXT - Installation • When installing the water connection (bypass or manifold) first connect to the plumbing system. Allow heated parts to cool and cemented parts to set before installing any plastic parts. Do not get primer or solvent on O-rings, nuts, or the valve.
  • Page 37: Integration Constraints

    Installer Manual Fleck 5600 - SXT - Installation • The riser tube should be cut flush with the top of the tank. Slightly bevel the ridge in order to avoid deterioration of the seal whilst fitting the valve. • The drain line must be a minimum of 12.7 mm (½") in diameter. Use 19 mm (¾") pipe if the backwash flow rate is greater than 26.5 lpm (7 gpm) or the pipe length is greater than 6 m ...
  • Page 38: Top-Mounted Valve Installation

    Installer Manual Fleck 5600 - SXT - Installation 5.5.1. Top-mounted valve installation When pressurized, any composite tank will expand both vertically and circumferential. In order to compensate the vertical expansion, the piping connections to the valve must be flexible enough to avoid overstress on the valve and tank.
  • Page 39 • In any case, any failure caused by improper installation and/or piping connections may void the warranty of Pentair products. • In the same way, using lubricant* on the valve thread is not allowed and will void the warranty for the valve and tank.
  • Page 40: Block Diagram And Configuration Example

    Installer Manual Fleck 5600 - SXT - Installation 5.6. Block diagram and configuration example Configuration example VC56SE SXT 27833 21675 18168 Block diagram By-pass Main inlet Gauge Gauge User’s line Check valve to prevent water hammer and eventual hot water returns. Turbine Mixing Drain...
  • Page 41: Regeneration Types

    Installer Manual Fleck 5600 - SXT - Installation 5.7. Regeneration types Metered immediate control A meter immediate control measures water usage and regenerates the system as soon as the calculated system capacity is depleted. The control calculates the system capacity by dividing the unit capacity (typically expressed in grains/unit volume) by the feedwater hardness and subtracting the reserve.
  • Page 42: Electrical Connections

    Installer Manual Fleck 5600 - SXT - Installation 5.8. Electrical connections 5.8.1. Downflow configuration W1: Black W2: Red W3: Green W4: Yellow W5: White W6: Blue W7: Orange W8: Violet Note The microswitch SW2 is connected on C and NC. 42 / 92 Ref.
  • Page 43: Upflow Configuration

    Installer Manual Fleck 5600 - SXT - Installation 5.8.2. Upflow configuration W1: Black W2: Red W3: Green W4: Yellow W5: White W6: Blue W7: Orange W8: Violet Note The microswitch SW2 is connected on C and NO. Ref. MKT-IM-013 / A - 21.12.2016 43 / 92...
  • Page 44: By-Passing

    Installer Manual Fleck 5600 - SXT - Installation 5.9. By-passing A bypass valve system should be installed on all water conditioning systems. Bypass valves isolate the softener from the water system and allow unconditioned water to be used. Service or routine maintenance procedures may also require that the system is bypassed.
  • Page 45: Drain Line Connection

    Installer Manual Fleck 5600 - SXT - Installation 5.10. Drain line connection Note Standard commercial practices are expressed here. Local codes may require changes to the following suggestions. Check with local authorities before installing a system. Preferably, the unit should not be more than 6.1 m from the drain. Use an appropriate adapter fitting to connect plastic tubing to the drain line connection of the valve.
  • Page 46: Overflow Line Connection

    Installer Manual Fleck 5600 - SXT - Installation 5.11. Overflow line connection In the event of a malfunction, power failure, etc, the brine tank overflow fitting will direct “overflow” to the drain instead of spilling on the floor. This fitting should be on the side of the cabinet or brine tank.
  • Page 47: Programming

    Installer Manual Fleck 5600 - SXT - Programming Programming 6.1. Display 1. Service icon → Appears in service mode; → Flashes if a regeneration cycle has been queued. 2. Error / → Appears in case of error, see page 75, or in diagnostic mode, see Information icon page 58.
  • Page 48: Commands

    Installer Manual Fleck 5600 - SXT - Programming 4. Data display 5. PM indicator → Appears if controller set in US unit. 6. Flow indicator → Flashes when outlet flow is detected. 7. x1000 indicator → Appears when the displayed number is bigger than 9999. 8.
  • Page 49: Reserve Capacity (Rc) Or (Sf)

    Installer Manual Fleck 5600 - SXT - Programming 6.4.4. Reserve capacity (RC) or (SF) Determine the reserve capacity in litre or in percentage. Adjust the reserve capacity with Press to validate the selection and advance to the next parameter. 6.4.5. Current day of the week (CD) Determine the day of regeneration.
  • Page 50 Installer Manual Fleck 5600 - SXT - Programming Parameter Options Definition Note Std DF single dF1b backwash Std DF double dF2b backwash Regeneration FLtr Filter To be used with standard piston only. flow UFbd UF brine first UFlt UF filter To be used with UF piston only.
  • Page 51: Entering Master Programming Mode

    Installer Manual Fleck 5600 - SXT - Programming Parameter Options Definition Note Regeneration 00:00:00 to Regeneration time will not appear Hour time 23:59:59 unless regeneration day override is on. First backwash Only displayed for dF2b regeneration Second flow. backwash Brine draw Brine fill 0 to 199 Minute...
  • Page 52: Display Format Mode (Df)

    Installer Manual Fleck 5600 - SXT - Programming 6.5.3. Display format mode (DF) Select the unit of measure. Options: • GAL: U.S. Gallons and 12-Hour AM/PM; • Ltr; Liters and 24-Hour. Press to select the unit. Press to validate the selection and move to the next parameter. 6.5.4.
  • Page 53: Valve Type (Nt)

    Installer Manual Fleck 5600 - SXT - Programming 6.5.6. Number of tanks (NT) Select the number of tanks. Options: • NT 1: Single tank system; • NT 2: Double tanks system. Mandatory Due to the 5600 valve being designed for single tank system only, set valve type to 1. Press until "---1"...
  • Page 54: Feedwater Hardness (H)

    Installer Manual Fleck 5600 - SXT - Programming 6.5.9. Feedwater hardness (H) Set the feedwater hardness. Note The feedwater hardness parameter is only available if the controller type has been programmed for volumetric regeneration. Mandatory Enter the feedwater hardness in °TH, ppm or grains of hardness for softener system. Note...
  • Page 55: Days Override (Do)

    Installer Manual Fleck 5600 - SXT - Programming 6.5.10.2 Reserve capacity (RC) Note This parameter is not shown if RS is set to SF. The fixed reserve capacity can be set up to a volume equivalent to 50% of the initial volumetric capacity.
  • Page 56: Regeneration Cycle Step Duration

    Installer Manual Fleck 5600 - SXT - Programming 6.5.13. Regeneration cycle step duration Set the duration in minutes of each regeneration cycle. Note Setting a cycle step to 0 will cause the controller to skip that step during regeneration, but keeps the following steps available.
  • Page 57: Current Day (Cd)

    Installer Manual Fleck 5600 - SXT - Programming 6.5.15. Current day (CD) Set the current day. Note The current day is defined from D1(Monday) to D7 (Sunday). AG Press to set the current day. AH Press to validate the selection and move to the next parameter. 6.5.16.
  • Page 58: Filter Programming

    Installer Manual Fleck 5600 - SXT - Programming 6.6. Filter programming To use the valve as a filter, in the master programming mode, set the regeneration mode (RF) to filter (FLtr). The controller will let set only the steps necessary to the filter mode, which are: regeneration control type (CT), days override (DO), regeneration time (RT), backwash (BW), rapid rinse (RR), day of week (Dn) and current day (CD).
  • Page 59: Hours Since Last Regeneration (Hr)

    Installer Manual Fleck 5600 - SXT - Programming 6.7.4. Hours since last regeneration (HR) Note Shows the number of hours since the last regeneration, indicating the length of the current service cycle. Hours since last regeneration display: 6.7.5. Volume since last regeneration (VU) Note...
  • Page 60: Resetting The Controller

    Installer Manual Fleck 5600 - SXT - Programming 6.8. Resetting the controller Note There are two methods to reset. 6.8.1. Soft reset (SR) Caution All the parameters are set to default values, except volume remaining in volumetric systems and days since last regeneration in time clock systems. Press and hold for 25 seconds while in normal service mode until SR is displayed.
  • Page 61: Commissioning

    Installer Manual Fleck 5600 - SXT - Commissioning Commissioning Note This chapter is available for standard regeneration types. Contact your supplier if the actual regeneration is not standard and if you need assistance. 7.1. Water filling, draining and waterproofness inspection 7.1.1.
  • Page 62: Additional Tips

    Installer Manual Fleck 5600 - SXT - Commissioning With the brine tank completely refilled and full of salt, adjust the safety brine valve in the brine well. Make sure the overflow elbow is installed above the float level. M After the softener has been running a few minutes in service, proceed to hardness test on outlet water to make sure the water is treated as per requirements.
  • Page 63: Electro Chlorination

    Installer Manual Fleck 5600 - SXT - Commissioning Calcium hypochlorite Calcium hypochlorite, 70% available chlorine, is available in several forms including tablets and granules. These solid materials may be used directly without dissolving before use. Do not let the disinfectant stand for more than 3 hours in the brine tank before the regeneration start. Dosage Measure two grains ~ 0.11 mL for 1 L.
  • Page 64: Operation

    Installer Manual Fleck 5600 - SXT - Operation Operation 8.1. Display during operation Examples: • Valve in service with day time: • Valve in service with volume remaining before regeneration: • Remaining days before next regeneration: • In volumetric regeneration mode, reserve 1223 litres remaining: •...
  • Page 65: Manual Regeneration

    Installer Manual Fleck 5600 - SXT - Operation 8.3. Manual regeneration Mandatory The controller must be in service in order to enable this procedure. 8.3.1. Manual delayed regeneration Press once for delayed regeneration. → The regeneration starts at the programmed regeneration time. See chapter 6.5.12. Regeneration time (RT), page 55.
  • Page 66: Maintenance

    Installer Manual Fleck 5600 - SXT - Maintenance Maintenance Mandatory Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper functioning of the complete system, and be documented in the Maintenance chapter in the User Guide document. 9.1.
  • Page 67: Replacing The Controller

    Installer Manual Fleck 5600 - SXT - Maintenance 9.2.2. Replacing the controller Operation Using a Philips screwdriver, unscrew (1) and remove the cover (2) paying attention for the wire. Press the board clips (3) and release the controller cover (6). Using a flat screwdriver, unscrew (5) and remove the controller (4).
  • Page 68: Replacing The Piston And/Or The Brine Valve

    Installer Manual Fleck 5600 - SXT - Maintenance 9.2.3. Replacing the piston and/or the brine valve Operation Disconnect the meter cable (1), if available. Using a flat screwdriver, unscrew (5) and remove the cover (4). Using a flat screwdriver, unscrew (3) and remove the washer (2). Using a flat screwdriver or a 8 mm wrench, unscrew (7) and remove the power head (6) from the valve body (8).
  • Page 69 Installer Manual Fleck 5600 - SXT - Maintenance Ref. MKT-IM-013 / A - 21.12.2016 69 / 92...
  • Page 70: Replacing The Seals And Spacers Cartridge

    Installer Manual Fleck 5600 - SXT - Maintenance 9.2.4. Replacing the seals and spacers cartridge Caution Use only approved silicon grease or soapy water. Operation Remove the piston, see“Replacing the controller motor”, page 73. Using a small hook, remove a seal (3). Using the puller (1), remove a spacer (4).
  • Page 71 Installer Manual Fleck 5600 - SXT - Maintenance Ref. MKT-IM-013 / A - 21.12.2016 71 / 92...
  • Page 72: Replacing The Microswitches And/Or The Drive Cam

    Installer Manual Fleck 5600 - SXT - Maintenance 9.2.5. Replacing the microswitches and/or the drive cam Operation Using a Philips screwdriver, unscrew (1) and remove the cover (2). Disconnect the wire on the microswitches (6). Using a Philips screwdriver, unscrew (8). Remove the protection plate (7) and the micorswitches (6).
  • Page 73: Replacing The Controller Motor

    Installer Manual Fleck 5600 - SXT - Maintenance 9.2.6. Replacing the controller motor Operation Using a flat screwdriver, unscrew (4) and remove the cover (3). Disconnect the motor (1). Using a Philips screwdriver, unscrew (2) and remove the motor (1). Change the motor (1).
  • Page 74: Replacing The Brine Cam

    Installer Manual Fleck 5600 - SXT - Maintenance 9.2.7. Replacing the brine cam Operation Remove the power head, see“Replacing the controller motor”, page 73. Using a flat screwdriver, unscrew (1). Remove the washer (2) and the brine cam (3). Change the brine cam (3). Reverse above procedure steps to rebuild.
  • Page 75: Cleaning The Injector

    Installer Manual Fleck 5600 - SXT - Maintenance 9.2.8. Cleaning the injector Operation Using a flat screwdriver or a 8 mm wrench, remove the screws (6). Remove the cap injector (5). Remove the seal (4). Remove the filter (2). Using a flat screwdriver, remove the injector nozzle (3). Using a flat screwdriver, remove the injector throat (1).
  • Page 76: Blfc Cleaning

    Installer Manual Fleck 5600 - SXT - Maintenance 9.2.9. BLFC cleaning Operation Using a wrench, remove the BLFC holder (1). Using pliers, remove the cage (4) form the BLCF holder (1). Remove the BLFC washer (3) from the BLFC holder (1). Clean the BLFC washer (3) with a terry cloth.
  • Page 77: Troubleshooting

    Installer Manual Fleck 5600 - SXT - Troubleshooting Troubleshooting Problem Cause Solution Interrupted power or switched off Restore the controller and connect to power source. constant power source. Check connections in the power head Disconnected / faulty meter cable. and on the meter cover. Change the Softener fails to cable.
  • Page 78 Installer Manual Fleck 5600 - SXT - Troubleshooting Problem Cause Solution Check backwash, brine draw, and The resin bed is dirty. brine refill. Regenerate more often Iron presence in and increase backwash cycle time. the valve Iron concentration exceeds Contact your local dealer. recommended parameters.
  • Page 79: Error Detection

    Installer Manual Fleck 5600 - SXT - Troubleshooting 10.1. Error detection Errors codes appear on the service display. Note It can take up to 1 minute before an error can be detected and displayed. 10.2. Error types and causes 10.2.1. Motor stall / cam sense error Note...
  • Page 80: Regeneration Failure

    Installer Manual Fleck 5600 - SXT - Troubleshooting 10.2.3. Regeneration failure Note The system has not regenerated for more than 99 days or 7 days if the controller type has been set to day of week. Perform a manual regeneration to reset the error code. If the system is metered, verify that it is measuring flow by running service water and watching for the flow indicator on the display.
  • Page 81: Spare Parts

    Installer Manual Fleck 5600 - SXT - Spare parts Spare parts 11.1. Safety brine valves list 2300 2310 BV 44 Brine Packaging Item Part number Description System quantity 27833 Safety Brine Valve 2300 - Without Air-Check 27834 Safety Brine Valve 2300 - HW - Without Air-Check 1600 60067-03 Safety Brine Valve 2310 - Without Air-Check...
  • Page 82: Valve Parts List

    Installer Manual Fleck 5600 - SXT - Spare parts 11.2. Valve parts list 82 / 92 Ref. MKT-IM-013 / A - 21.12.2016...
  • Page 83 Installer Manual Fleck 5600 - SXT - Spare parts Packaging Item Part number Description quantity Valve Body assembly 5600 Filter BU28520-01 Valve Body assembly 5600 with Mixing BU28520-02 Valve Body assembly 5600 LWU with Mixing BU28520-03 Valve Body assembly 5600 FR with Mixing BU28520-04 Valve Body assembly 5600 UF with Mixing BU28520-05...
  • Page 84: Power Head Parts List

    Installer Manual Fleck 5600 - SXT - Spare parts 11.3. Power head parts list 84 / 92 Ref. MKT-IM-013 / A - 21.12.2016...
  • Page 85 Installer Manual Fleck 5600 - SXT - Spare parts Packaging Item Part number Description quantity PH56SXT-001 Power Head 4600/5600 SXT Time Clock DF PH56SXT-002 Power Head 4600/5600 SXT Time Clock UF PH56SXT-003 Power Head 4600/5600 SXT Econominder DF PH56SXT-004 Power Head 4600/5600 SXT Econominder UF Drive Motor assembly 24 V/50 Hz 2 RPM Replacement 25329 11384...
  • Page 86: Safety Brine Valve Parts List

    Installer Manual Fleck 5600 - SXT - Spare parts 11.4. Safety brine valve parts list Packaging Item Part number Description quantity 60014 Safety brine assembly, 2310 26746 Elbow assembly, safety brine valve 11183 O-ring-017 19625 Brine Valve 1650 Plastic Nut assembly 19649 Flow disperser PWG19652-01...
  • Page 87: Plastic Turbine Meter Assembly Parts List

    Installer Manual Fleck 5600 - SXT - Spare parts Packaging Item Part number Description quantity 10150 Grommet pass rod 2300/2310/ 2350 18168 Air Check 500 (0,915 m) 26773 Air Check 500 (1,25 m) 23473 Air Check 500 (0,915 m) HW 11.5.
  • Page 88: Bypass

    Installer Manual Fleck 5600 - SXT - Spare parts 11.6. Bypass 11.6.1. 1" BSP female stainless steel bypass parts list 88 / 92 Ref. MKT-IM-013 / A - 21.12.2016...
  • Page 89 Installer Manual Fleck 5600 - SXT - Spare parts Packaging Item Part number Description quantity BU28502 Bypass Stainless Steel 1" BSP Screw Hex Hd Mach 1/4-20 X 1 Or Slot Hex 13386 Bypass handle red 24419-10 Screw, Hex washer head 10-24 x 0.5" 15727 Label bypass standard 13604-01...
  • Page 90: Plastic Bypass (No Yoke) Parts List

    Installer Manual Fleck 5600 - SXT - Spare parts 11.6.2. Plastic bypass (no yoke) parts list Packaging Item Part number Description quantity Bypass plastic BU26054 Screw, slot ind, hex, 8-18 x 0.60" 13314 Clip mounting BU13255 O-ring-119 13305 Yoke, 1", BSP, male, plastic 18706-10 Yoke, ¾", BSP, male, plastic 18706-12...
  • Page 91: Scrapping

    This will help to reduce the impact on the environment, health, safety and help to promote recycling. Pentair does not collect used product for recycling. Contact your local recycling center for more information.
  • Page 92 www.pentairaquaeurope.com...

Table of Contents