MASTER PROGRAMMING MODE FLOW
Range:
00:00:00 to 18:00:00
CHART continued
NOTE: Only displayed if Auxiliary Relay is enabled in previous screen.
Auxiliary Relay will only display if Chemical Pump is OFF for System
Types 6 & 7.
Range:
00:00:00 to 18:00:00
Options: Enabled
Disabled (Default)
NOTE: This screen will only display on the lead unit for System Types 6 & 7.
For all other System Types, it will display for all units.
Range:
000 to 999 gallons in U.S. Format
0.000 to 9.999 L in Metric Format
NOTE: Only displayed on units that physically have a meter (Lead always has
a meter). Only shown if Auxiliary Relay is disabled on System Types 6 & 7.
Range:
00:00:00 to 02:00:00
Options: 1.2 Turbine
Generic
NOTES: Default flow meter type is based on the valve type. This screen will
only display on the lead unit for System Types 6 & 7. All other system types
it will display for all units.
Range:
20 - 2,000 gpm (U.S. Format)
2.0 - 200.0 L (Metric Format)
NOTE: Only displayed if "Generic" is chosen for the flow meter.
Options: Gallons (U.S. Format)
Liters (Metric Format)
Range:
1 - 99 Gallons (U.S. Format)
0.1 - 09.9 L (Metric Format)
Pulses: 1 - 99
NOTE: Only displayed if "Generic" is chosen for the flow meter.
10 • FLECK 7000 NXT Service Manual
Example:
Auxiliary Relay Output in Start 1 at
0 hours, 0 minutes, & 0 seconds
Example:
Auxiliary Relay Output in End 1 at
0 hours, 0 minutes, & 0 seconds
Example:
Chemical Pump is Disabled
Example:
Chemical Pump Auxiliary Relay
Volume at 0 Gallons
Example:
Chemical Pump Auxiliary Relay at 0 Hours,
0 Minutes, & 0 Seconds
Example:
1.2 Turbine Flow Meter
Example:
Maximum Flow Rate of 0 gpm
Example:
Add 1 Gallon for Each Pulse in U.S. Format
Example:
Master Programming Mode is Exiting

MASTER PROGRAMMING GUIDE

When the Master Programming Mode is entered, parameters
can be set to make the timer(s) function as needed.
NOTE: Depending on current option settings, some displays
cannot be viewed or set.
Entering Master Programming Mode:
1. Press and hold the Shift and Up buttons for 5 seconds.
OR
2. Set the time of day display to 12:01 PM or 12:01HR (See the
"Setting the Time of Day" section on the "Timer Operation"
page). Then go to the main display screen, press the Up and
Down buttons at the same time for 5 seconds.
Exiting Master Programming Mode
1. Press the Extra Cycle button once per display until all
are viewed. Master Programming Mode is exited and the
normal display screen appears.
2. To exit the Master Programming Mode without saving
changes, press the Diagnostic button.
NOTE: If no keypad activity is made for 5 minutes while in
the Master Programming Mode, or if there is a power
failure, no changes will be saved, and the unit will go
back to the main display screen.
Resets
Soft Reset: Press and hold the Up and Down buttons for 25
seconds until 12:00PM (or 12:00HR) appears. This resets all
parameters except for the flow meter totalizer volume.
Master Reset: Hold the Extra Cycle button while powering up
the unit. This resets all of the parameters in the unit. Check
and verify the choices selected in Master Programming Mode
prior to this procedure.
1. Choice of Language
This option selects the language for programming and display.
1. Use Up or Down to select language.
2. Press the Extra Cycle button.
2. System Type
This program type selects the system type (4, 5, 6, 7, or 9).
1. Use Up or Down buttons to adjust this value.
2. Press the Extra Cycle button.
3. Valve Address
This program step selects the valve address (1, 2, 3, or 4)
within the network. The address is needed for each timer
for communication. The #1 is the "master" or "lead" which
contains programmed parameters, that will be used by all of
the timer(s) in the network to control Regeneration, in Service,
or Standby of all the valve(s) in the system. This option will be
skipped if System 4 is selected.
1. Use Up or Down buttons to adjust this value.
2. Press the Extra Cycle button.