Lopi ProBuilder 24 CleanFace GSR2 Installation Manual page 57

Hide thumbs Also See for ProBuilder 24 CleanFace GSR2:
Table of Contents

Advertisement

3. Remove the manifold covers.
NOTE: Reinstall the manifold cover after changing the orifices
4. Follow the directions below to replace the orifice.
a
Slide the air shutters to provide access to the orifices.
b
Remove and discard the two gaskets on the front burner orifice.
Adjustable Wrench
Orifice
e
Screw each LP orifice until orifice
protrudes 15/16" (23.8mm)
indicating full insertion (use
wrench to support manifold when
re-attaching orifice).
© Travis Industries
Installation
Use a adjustable wrench to support the
c
manifold while removing each
orifice with a 1/2" wrench.
1/2" Open End Wrench
Manifold
(for qualified installers only)
Apply thread sealant to the LP orifices
prior to installation. Use the chart below to
identify the correct orifices.
15/16"
Look here for the orifice identification
23.8mm
12/17/20 - 1528
d
24PB Orifice Numbers
NG
LP
#47
#56
PB24 CF Install (AUST)