Nortel Communication Server 1000S Installation And Configuration Manual page 65

Isdn basic rate interface
Hide thumbs Also See for Communication Server 1000S:
Table of Contents

Advertisement

Figure 15
Jumper plug settings for reverse power on the TX and RX leads
No power on the TX and RX leads. This option applies when the
terminal is powered locally with an adapter provided with the
terminal. It also applies when a SILC DSL is used for trunking.
Remove the jumper plugs and store them on J1 to implement this
option.
5
Insert the SILC or UILC into the selected card slot and lock it in place.
6
Observe the behaviors of the LED on the faceplate of the MISP to
determine its status:
The LED lights, flashes three times, and then remains lit – indicates
the card is operating correctly, but is not configured.
The LED lights, flashes three times, and then turns off – indicates the
card is operating correctly and is configured.
Any other LED behavior suggests a defective circuit card.
7
Repeat the steps in this procedure for each SILC or UILC being installed.
ISDN Basic Rate Interface
Configuring ISDN BRI hardware
Jumper plugs
BRTN RX
TX PWR
End of Procedure
Page 65 of 120
553-7581.EPS