Installing ISDN BRI hardware
553-3001-218
Standard 2.00
3
Slide the BRSC, SILC, or UILC into the module until it engages the
backplane connector.
4
Push the card firmly into the connector using the locking devices as levers
by pushing them toward the card's front panel.
5
Push the tabs firmly against the front panel of the card so they latch to the
front lip in the module and to the post on the card.
6
Observe the red LED located on the faceplate.
If the red LED turns on and stays lit continuously, the card is
defective. Remove the card, choose a new card, and repeat the
installation procedure.
If it flashes three times and then turns off, the card is operating
correctly. Go to step 7.
If the red LED flashes three times and then stays lit continuously, the
card is operating correctly but is not configured. Go to step 7.
7
On the CE or IPE Module card location form, fill in the card type and the
module number next to the slot number of the installed card.
8
Repeat steps 1 through 7 for each card requiring installation.
Procedure 6
Remove the BRSC, SILC, and UILC
Perform the following steps to remove the BRSC, SILC, and the UILC.
1
Hold the card by its card-locking devices. Squeeze the tabs to unlatch the
card-locking devices and lift them away from the card.
2
Carefully disengage the BRSC, SILC, or UILC from the backplane
connector, and slowly slide the card from the module.
September 2004
End of Procedure
End of Procedure