Name
By setting a value other than "9999", set speeds 4 to 7.
Multi-speed setting
24
ON/OFF of the contact signals (RH, RM, RL signals) are combined to change the
(speed 4)
running speed in stages.
Multi-speed setting
25
(speed 5)
Multi-speed setting
26
(speed 6)
Multi-speed setting
27
(speed 7)
0 to 3600r/min, 9999
The multiple speeds can be increased or overridden for compensation.
Multi-speed input
28
0: Without compensation
compensation
1: With compensation
Determines the frequency changing pattern for acceleration/deceleration.
0: Linear acceleration/deceleration
Acceleration/
1: S-pattern acceleration/deceleration A
29
deceleration pattern
2: S-pattern acceleration/deceleration B
3: Backlash measures acceleration/deceleration
4: S-pattern acceleration/deceleration C
Set when using the FR-ABR, FR-HC or FR-CV option for frequent start/stop operation.
0: Internal brake resistor, brake unit
Regenerative
30
1: Brake resistor (FR-ABR)
function selection
2: High power factor converter (FR-HC), power regeneration common converter (FR-
CV)
31 Speed jump 1A
32 Speed jump 1B
Set the speed ranges you want to avoid during constant-speed operation to avoid
33 Speed jump 2A
resonance with the machine.
34 Speed jump 2B
0 to 3600r/min, 9999
35 Speed jump 3A
36 Speed jump 3B
Display the machine speed and output speed.
37 Speed display
0: Output speed
1 to 9998: Machine speed at the Pr. 505 set speed operation
You can adjust the output signal on/off range when the output speed reaches the
Up-to-speed
41
running speed.
sensitivity
0 to 100%
You can adjust the speed detected.
42 Speed detection
0 to 3600r/min
You can change the speed detection level for forward or reverse rotation in vertical lift,
Speed detection for
43
transfer and other applications.
reverse rotation
0 to 3600r/min, 9999
Second acceleration/
Second function of the acceleration/deceleration time set in Pr. 7, Pr. 8.
44
0 to 3600s/0 to 360s
deceleration time
Second deceleration
Second function of the deceleration time set in Pr. 8.
45
0 to 3600s/0 to 360s, 9999
time
Second speed
Set the speed at which the FB2 signal is output.
50
0 to 3600r/min
detection
Outline
RH
RM
RL
Speed 4
OFF
ON
ON
Speed 5
ON
OFF
ON
Speed 6
ON
ON
OFF
Speed 7
ON
ON
ON
59
Function list (Extended function parameters)
Cus-
Factory
tomer
Setting
Set-
ting
9999
9999
9999
9999
0
0
0
9999
9999
9999
9999
9999
9999
0
10%
300r/min
9999
5s
9999
750r/min
At-a-glance Guide to
Functions
: Usable function
× : Unusable function
* : Functions that can be used
for parameter-set position
control
Vector Control
Speed
Torque
Position
control
control
control
×
*
×
*
×
*
×
*
×
×
×
×
×
×
×
×
×
×
×
*
×
*