Mitsubishi Electric FR-V500 Series Instruction Manual page 72

Vector inverter
Hide thumbs Also See for FR-V500 Series:
Table of Contents

Advertisement

Name
Digital position
Set the time until the inverter stops when the forward rotation (reverse rotation)
464
control sudden stop
command is turned off with the position feed forward function.
deceleration time
0 to 360.0s
First position feed
465
Parameters for setting position feed data for parameter-based
amount lower 4 digits
position control.
First position feed
466
amount upper 4 digits
No.
Second position feed
467
465
amount lower 4 digits
466
Second position feed
468
467
amount upper 4 digits
468
Third position feed
469
amount lower 4 digits
469
Third position feed
470
470
amount upper 4 digits
471
Fourth position feed
472
471
amount lower 4 digits
473
Fourth position feed
474
472
amount upper 4 digits
475
476
Fifth position feed
473
amount lower 4 digits
477
478
Fifth position feed
474
479
amount upper 4 digits
480
Sixth position feed
475
481
amount lower 4 digits
482
Sixth position feed
476
483
amount upper 4 digits
484
Seventh position feed
477
485
amount lower 4 digits
486
Seventh position feed
478
487
amount upper 4 digits
488
Eighth position feed
489
479
amount lower 4 digits
490
Eighth position feed
491
480
amount upper 4 digits
492
Ninth position feed
493
481
amount lower 4 digits
494
Ninth position feed
482
amount upper 4 digits
Tenth position feed
483
amount lower 4 digits
Tenth position feed
484
amount upper 4 digits
Eleventh position feed
485
amount lower 4 digits
Eleventh position feed
486
amount upper 4 digits
Twelfth position feed
487
amount lower 4 digits
Twelfth position feed
488
amount upper 4 digits
Thirteenth position
489
feed amount lower 4
digits
Thirteenth position
490
feed amount upper 4
digits
Fourteenth position
491
feed amount lower 4
digits
Fourteenth position
492
feed amount upper 4
digits
Fifteenth position feed
493
amount lower 4 digits
Fifteenth position feed
494
amount upper 4 digits
You can turn on/off the inverter output.
Remote output
495
0: Non-latch
selection
1: Latch
496 Remote output data 1
You can set the output signal data of the inverter.
0 to 4095
497 Remote output data 2
Outline
Selection Method
Setting
Range
Feed Speed
REX
RH
RM
RL
0 to 9999
High speed,
OFF
ON
OFF
OFF
0 to 9999
0 to 9999
OFF
OFF
ON
OFF
0 to 9999
0 to 9999
Low speed,
OFF
OFF
OFF
ON
0 to 9999
0 to 9999
OFF
OFF
ON
ON
0 to 9999
0 to 9999
OFF
ON
OFF
ON
0 to 9999
0 to 9999
OFF
ON
ON
OFF
0 to 9999
0 to 9999
OFF
ON
ON
ON
0 to 9999
0 to 9999
ON
OFF
OFF
OFF
0 to 9999
0 to 9999
ON
OFF
OFF
ON
0 to 9999
0 to 9999
ON
OFF
ON
OFF
0 to 9999
0 to 9999
ON
OFF
ON
ON
0 to 9999
0 to 9999
ON
ON
OFF
OFF
0 to 9999
0 to 9999
ON
ON
OFF
ON
0 to 9999
0 to 9999
ON
ON
ON
OFF
0 to 9999
0 to 9999
ON
ON
ON
ON
0 to 9999
69
Function list (Extended function parameters)
Factory
Setting
0
0
0
Position
0
Pr. 4
0
Middle
speed,
Pr. 5
0
Pr. 6
0
Speed 4,
Pr. 24
0
Speed 5,
Pr. 25
0
Speed 6,
Pr. 26
0
Speed 7,
Pr. 27
0
Speed 8,
Pr. 232
0
Speed 9,
Pr. 233
0
Speed 10,
Pr. 234
0
Speed 11,
Pr. 235
Speed 12,
0
Pr. 236
Speed 13,
0
Pr. 237
Speed 14,
0
Pr. 238
Speed 15,
0
Pr. 239
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
At-a-glance Guide to
Functions
: Usable function
× : Unusable function
Cus-
* : Functions that can be used
tomer
for parameter-set position
Set-
control
ting
Vector Control
Speed
Torque
Position
control
control
control
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
5