Mitsubishi Electric FR-V500 Series Instruction Manual page 28

Vector inverter
Hide thumbs Also See for FR-V500 Series:
Table of Contents

Advertisement

External jog operation
Keep the start switch (STF or STR) on to perform operation, and turn it off to stop.
1)Set Pr. 15 "jog speed setting" and Pr. 16 "jog acceleration/deceleration time".
2)Select the external operation mode.
3)Switch on the jog signal. Keep the start switch (STF or STR) on to perform operation.
Assign the terminal used for the jog signal in any of Pr. 180 to Pr. 183 and Pr. 187
(input terminal function selection). (Refer to page 65.)
(3) Choosing external/PU combined operation mode 1 (operation using the external start
signal and control panel)
When setting the start signals from outside inverter (e.g. switches or relays) and the
running speed from the control panel (Pr. 79 = 3)
•Run command: start signal connected outside
•Speed setting:
For multi-speed command, refer to Pr.4 to Pr.6 on page 54.
1.
Power on
Switch power on.
Operation mode selection
2.
Set "3" in Pr. 79 "operation mode selection".
(Refer to page 56 for details of Pr.79.)
The combined operation mode is selected and the operation
status indication "EXT" and "PU" are lit.
3.
Start
Turn on the start switch (STF or STR).
The operation status indication "FWD" or "REV" is lit.
REMARKS
• The motor does not start if both the forward and
reverse rotation switches are turned on. If both
switches are turned on during operation, the motor
decelerates to a stop.
• Set the speed in the speed setting mode
4.
Running speed setting
Using
, of PU, set the running speed to 150r/min
and press
.
SET
The run command indication FWD or REV is lit.
5.
Stop
Turn off the start switch (STF or STR).
The motor decelerates to stop.
The operation status indication "FWD" or "REV" is lit.
CAUTION
When Pr. 75 "PU stop selection" = "14 to 17",
STOP
is valid.
RESET
REMARKS
When setting the start signal from the PU and speed setting signal from outside inverter, set
"
in Pr.79
operation mode selection
of PU or multi-speed command (multi-speed command has priority)
Operation
(Refer to page 28.).
"
.
Basic operation (Speed setting, run,
speed meter adjustment)
ON
Forward
rotation Reverse
rotation
ON
SET
Forward
rotation Reverse
rotation
OFF
25
Display
Flicker
FR-DU04
-1
CONTROL PANEL
Hz/r
A
V
MON
EXT
PU
REV
FWD
FR-DU04
CONTROL PANEL
-1
Hz/r
A
V
MON
EXT
PU
REV
FWD
FR-DU04
CONTROL PANEL
-1
Hz/r
A
V
MON
EXT
PU
REV
FWD
"
" (
4
combined operation mode 2
3
)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents