Mitsubishi Electric FR-V500 Series Instruction Manual page 24

Vector inverter
Hide thumbs Also See for FR-V500 Series:
Table of Contents

Advertisement

REMARKS
When using a conventional motor (SF-VR, SF-JR) or other motors, refer to the
Instruction Manual (detailed).
<At-a-glance guide to setting the motor>
Parameter,
Jumper
No.
Item
Connector,
Terminal
Motor
1
Pr. 71 setting
setting
Offline
2
tuning
1 :1
Capacity
3
Pr. 80 setting
setting
1 rank
lower
Number
of
4
Pr. 851setting
encoder
pulses
Encoder
5
rotation
Pr. 852 setting
direction
Encoder
Power
Encoder
power
6
supply
power supply
supply
specification
jumper
specification
connector on
Output
the back of
Encoder
circuit
the control
7
output
Terminating
terminal
type
resistance
Electronic
8
thermal
Pr. 9 setting
relay
Across
Thermal
OH-SD
9
protector
input
Pr. 876 setting
CAUTION
1. Set number of motor poles in Pr.81.
2. Make setting according to the motor used.
3. The half-tone screened cells are factory set.
4. Check the power supply specification of encoder and change a jumper connector.
5. *:Perform offline auto tuning (mode without rotation) for the wiring length to be reflected on the
control when exercising magnetic flux observer and the wiring length is long (30m or longer as
reference).
<When using other manufacturers' motors>
Offline auto tuning (rotation mode) is necessary. Perform offline auto tuning with the motor alone before connecting
a load. If higher torque accuracy is required, perform online auto tuning next.
Offline auto tuning
The inverter measures necessary motor circuit constant and stores it to improve low speed
torque.
Online auto tuning
High torque accuracy corresponding to the motor temperature variation is available.
Dedicated Motor
Mitsubishi
SF-JR (with encoder)
SF-V5RU
SF-VR-
(2, 4, 6P)-
1500r/min
5.5kW to
2.2kW to
series
45kW
55kW
30
30
0
Not
Not
Not
required *
required *
required *
required *
INV
INV
INV
capacity
capacity
capacity
Motor
Motor
Motor
capacity
capacity
capacity
2048
1000
1024
1
1
1
12V
5V
5V
Complimentary Differential Differential Differential Differential
No
Yes
Yes
Rated
0
0
motor
current
Connect to
Connect to
Open
the thermal
the thermal
1
1
0
Standard Motor
Mitsubishi
manufacturer
SF-HR
Others
(4P)-
(with
(with
1.5kW or
encoder)
encoder)
encoder)
less
20
3 to 8
3 to 8
Not
Required
Required
Required
INV
INV
INV
capacity
capacity
capacity
capacity
Motor
Motor
Motor
capacity
capacity
capacity
capacity
1024
1024
(*2)
1
1
(*2)
5V
5V
(*2)
(*2)
Yes
Yes
(*2)
Rated
Rated
motor
motor
(*2)
current
current
Open
Open
(*2)
0
0
(*2)
21
Setting the motor
Constant-torque Motor
(with encoder)
Mitsubishi
Other
Other
SF-HRCA
SF-JRCA
(with
manufacturer
(4P) (with
(with
encoder)
encoder)
3 to 8
10
13 to 18
13 to 18
Not
Required Required
required *
INV
INV
INV
INV
capacity
capacity
capacity
Motor
Motor
Motor
Motor
capacity
capacity
capacity
(*2)
1024
1024
(*2)
(*2)
1
1
(*2)
(*2)
5V
5V
(*2)
(*2)
Differential Differential
(*2)
(*2)
Yes
Yes
(*2)
Rated
Rated
(*2)
motor
motor
(*2)
current
current
(*2)
Open
Open
(*2)
(*2)
0
0
(*2)
2