Mitsubishi Electric FR-V500 Series Instruction Manual page 65

Vector inverter
Hide thumbs Also See for FR-V500 Series:
Table of Contents

Advertisement

Function list (Extended function parameters)
Name
Reset selection/
disconnected PU
75
detection/PU stop
selection
Parameter write
77
disable selection
Reverse rotation
78
prevention selection
Operation mode
79
selection
80 Motor capacity
Number of motor
81
poles
Motor excitation
82
current (no load
current)
83 Rated motor voltage
Rated motor
84
frequency
90 Motor constant R1
91 Motor constant R2
92 Motor constant L1
93 Motor constant L2
94 Motor constant X
Online auto tuning
95
selection
Auto tuning setting/
96
status
Third acceleration/
110
deceleration time
Third deceleration
111
time
116 Third speed detection
You can select the reset input acceptance, disconnected PU detection function and PU
stop function.
Pr. 75
Reset Selection
Setting
0
Reset input is always enabled.
Reset input is enabled only when
1
the protective function is activated.
2
Reset input is always enabled.
Reset input is enabled only when
3
the protective function is activated.
14
Reset input is always enabled.
Reset input is enabled only when
15
the protective function is activated.
16
Reset input is always enabled.
Reset input is enabled only when
17
the protective function is activated.
0,1,2
This function can prevent reverse rotation fault resulting from the incorrect input of the
start signal.
0: Both forward rotation and reverse rotation enabled, 1: Reverse rotation disabled, 2:
Forward rotation disabled
0 to 4,6 to 8
Set the motor capacity.
0.4kW to 55kW
Set the number of motor poles.
2,4,6
Used for tuning data utilization or direct input.
Set the rated motor voltage.
0 to 1000V
Set the rated motor frequency.
10 to 200Hz
Used for tuning data utilization or direct input.
0,1,2
Perform motor auto tuning when a motor other than SF-V5RU,SF-VR,SF-JR or SF-
HRCA is used.
0,1,101
Third function of acceleration/deceleration time set in Pr. 7, Pr. 8
0 to 3600/0 to 360s
Third function of deceleration time set in Pr. 8
0 to 3600/0 to 360s, 9999
Set the speed at which the FB3 signal is output.
0 to 3600r/min
Outline
Disconnected
PU Stop
PU Detection
Selection
If the PU is
disconnected,
operation will be
Pressing
STOP
RESET
continued.
decelerates the motor
When the PU is
to a stop only in the
disconnected, the
PU operation mode.
inverter output is
shut off.
If the PU is
disconnected,
STOP
Pressing
RESET
operation will be
decelerates the motor
continued.
to a stop in any of the
When the PU is
PU, external and
disconnected, the
communication
inverter output is
operation modes.
shut off.
62
At-a-glance Guide to
Functions
: Usable function
× : Unusable function
Cus-
* : Functions that can be used
Factory
tomer
for parameter-set position
Setting
Set-
control
ting
Vector Control
Speed
Torque
control
control
14
0
0
0
Inverter
capacity
4
9999
200V/
400V
60Hz
9999
9999
9999
9999
9999
0
0
5s
9999
1500r/min
Position
control
×
*
×
*