Connection diagram, encoder cable,
PU connector
2.2.3
Encoder connection cable (FR-V5CBL)
When using a dedicated motor (SF-V5RU series), use an encoder cable (FR-V5CBL) for connection.
Inverter side
Earth (Ground) wire
FR-V500
PA
PAR
PB
PBR
PZ
PZR
PG
SD
2mm
2
Inverter earth (ground) terminal
2.2.4
Setting the encoder
When a dedicated encoder cable (FR-V5CBL) is used, a setting change may not be required.
CAUTION
Make setting correctly.
Fitting the jumper connector to the position exceeding the power specification results in an encoder
failure. Fitting the jumper connector to the position below the power specification results in an encoder
malfunction.
(1) Setting the power supply specification of the encoder and pulse output type
Switch the position of the jumper connector on the back surface of the control circuit terminal block according
to the encoder specification. (Refer to page 17 for removal and installation of the control circuit terminal block.)
CAUTION
• Encoder power supply jumper
connector
The jumper connector is fitted
to 12V when shipped from the
factory. Switch its position
according to power supply
specification.
REMARKS
Since the specification of the encorder
of the conventional motors (SF-VR,
SF-JR with encorder) is 5V, fit the
jumper connector to 5V.
Encoder side
connector
F-DPEVSB 12P×0.2mm
2
60
L
Encoder
A
FR-V5CBL5
B
C
FR-V5CBL15
D
F
FR-V5CBL30
G
Contact us separately for other lengths.
S
R
MS3057-12A
MS3106B20-29S
Type
Length L (m)
5
15
30
Positioning keyway
A
B
M
C
N
L
D
P
T
K
E
S
R
J
F
H
G
MS3106B20-29S
(As viewed from wiring side)
Power supply voltage is 5V
Power supply voltage is 12V
Power supply voltage is 24V
Power supply voltage is external
12
(Unit: mm )
Remarks
Standard product

Hide quick links: