Mitsubishi Electric FR-V500 Series Instruction Manual page 69

Vector inverter
Hide thumbs Also See for FR-V500 Series:
Table of Contents

Advertisement

Function list (Extended function parameters)
Name
Multi-speed setting
232
(speed 8)
Multi-speed setting
233
(speed 9)
Multi-speed setting
234
(speed 10)
Multi-speed setting
235
(speed 11)
Multi-speed setting
236
(speed 12)
Multi-speed setting
237
(speed 13)
Multi-speed setting
238
(speed 14)
Multi-speed setting
239
(speed 15)
240 Soft-PWM setting
Cooling fan operation
244
selection
250 Stop selection
Output phase failure
251
protection selection
252 Override bias
253 Override gain
Power failure stop
261
selection
Subtracted speed at
262
deceleration start
Subtraction starting
263
speed
Power-failure
264
deceleration time 1
Power-failure
265
deceleration time 2
Power-failure
266
deceleration time
switchover speed
278 Brake opening speed
Brake opening
279
current
Brake opening
280
current detection time
Brake operation time
281
at start
282 Brake operation speed
Brake operation time
283
at stop
Deceleration
284
detection function
selection
Overspeed detection
285
speed
By setting any value other than "9999", set speeds 8 to 15.
This function is designed to change the running speed in stages by changing the ON/
OFF combination of the contact signals (RH, RM, RL, REX signals).
RH
Speed 8
OFF
Speed 9
OFF
Speed 10
OFF
Speed 11
OFF
Speed 12
ON
Speed 13
ON
Speed 14
ON
Speed 15
ON
0 to 3600r/min, 9999
You can select to exercise Soft-PWM control and long wiring mode. When Soft-PWM
control is made valid, you can change the metallic tone of motor sound into an
unoffending complex tone. Surge voltage is surpressed in the long wiring mode
regardless of the wiring length between the inverter and motor. (When operating a
400V motor with wiring length of 40m or more, select long wiring mode.)
0: Soft-PWM control invalid, long wiring mode invalid
1: Soft-PWM control valid (when Pr. 72 = "1 or 2"), long wiring mode invalid
10: Soft-PWM control invalid, long wiring mode valid (carrier frequency is 2.25Hz *)
11: Soft-PWM control valid, long wiring mode valid (carrier frequency is 2.25Hz *)
*The Pr.72 "PWM frequency selection" setting is made invalid.
You can control the operation of the cooling fan built in the inverter.
0: The fan is always operated at power-on of the inverter.
1: The fan is always on while the inverter is running. During a stop, the inverter status is
monitored and the fan switches on-off according to the temperature.
Set to allow the motor to be coasted to a stop by turning off the start command during
V/F or speed control.
0 to 100s: Coasting to stop
9999: Deceleration to stop
You can disable the output phase failure protection function that stops the inverter
output if one of the inverter output side (load side) three phases (U, V, W) opens.
0: Without output phase failure protection
1: With output phase failure protection
When you selected the override in Pr. 73, you can adjust the override bias (0 to 200%)
and override gain (0 to 200%).
You can select the stopping method at a power failure.
0: Coasting to stop, inverter output shutoff
1: Inverter is decelerated to a stop.
0 to 600r/min
0 to 3600r/min, 9999
0 to 3600/0 to 360s
0 to 3600/0 to 360s, 9999
0 to 3600r/min
Set when outputting the operation timing signal of the mechanical brake in vertical lift
applications. (When speed control (invalid for V/F control) is selected)
0 to 900r/min (Pr. 278)
0 to 200% (Pr. 279)
0 to 2s (Pr. 280)
0 to 5s (Pr. 281)
0 to 900r/min (Pr. 282)
0 to 5s (Pr. 283)
0, 1 (Pr. 284)
0 to 900r/min, 9999 (Pr. 285)
Outline
RM
RL
REX
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
ON
66
At-a-glance Guide to
Functions
: Usable function
× : Unusable function
Cus-
* : Functions that can be used
Factory
tomer
for parameter-set position
Setting
Set-
control
ting
Vector Control
Speed
Torque
control
control
9999
9999
9999
9999
9999
9999
9999
9999
10
0
9999
1
50%
150%
0
90r/min
1500r/min
5s
9999
1500r/min
×
20r/min
×
130%
×
0.3s
×
0.3s
×
25r/min
×
0.3s
×
0
×
9999
Position
control
×
*
×
*
×
*
×
*
×
*
×
*
×
*
×
*
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×

Hide quick links:

Advertisement

Table of Contents
loading