2-4-2.

CCD Unit (HSC100R/100RF)

Note
Do not replace the CCD unit with the power turned on.
Before replacing the CCD unit, be sure to turn off the power switch and disconnect the TRIAX/optical fiber cable or
the cable connected to the DC IN connector.
Preparation
1.
Remove the outside panel assembly.
• HSC300R/100R: Refer
• HSC300RF/100RF: Refer
Procedure
1.
Disconnect the two flexible flat cables from the two connectors (CN001, CN003) on the TG-285 board.
Note
Be careful not to bend the flexible card wire. This shortens the wire life.
2.
Remove the four screws to detach the front assembly.
3.
Loosen the setscrew to detach the filter select knob.
HSC300RF/HSC100RF/HSC300R/HSC100R
to"2-2-1. Outside Panel Assembly (TRIAX)"
to"2-3-1. Outside Panel Assembly (Fiber)"
Flexible flat cables
CN003
TG-285 board
CN001
Front assembly
B3 x 10
B3 x 10
2-11