Preparation
• Setting for MSU-1000
DETAIL OFF button → ON (dark)
• Shoot the grayscale chart so that the chart frame is aligned with the under scanned monitor frame.
• Lens iris: A = 600 ±20 mV (F4 to F5.6)
If the lens aperture is greater than F5.6, adjust the light amount with the shutter.
Adjustment Procedure
1.
Operate the control panel of MSU-1000, and perform the automatic white balance adjustment.
WHITE button → ON (lit)
2.
Operate the menu of MSU-1000.
1)
PAINT button → ON (lit)
2)
Touch panel operation: (Page 1) → [Detail] → [1/3]
3.
Set Crispening to -99 once, and turn slowly for increment until the noise at the black level of the waveform just
decreases. Or adjust for the desired level.
3-4-4.

Level Dependent Adjustment

Equipment: Waveform monitor (R, G, B)
Test Point: SDI connector
Object: Grayscale chart
Preparation
• Setting for MSU-1000
DETAIL OFF button → ON (dark)
• Shoot the grayscale chart so that the chart frame is aligned with the under scanned monitor frame.
• Lens iris: A = 600 ±20 mV (F4 to F5.6)
If the lens aperture is greater than F5.6, adjust the light amount with the shutter.
HSC300RF/HSC100RF/HSC300R/HSC100R
A
A
3-18