Checking Correction Points
1.
Open the MANUAL RPN [S03] page of the SERVICE menu.
<MANUAL RPN>
RPN CH SELECT
RPN CURSOR
CURSOR H POS.
CURSOR V POS.
CURSOR JUMP
RPN WIDTH
RECORD RPN
DELETE RPN
MONITOR SEL
2.
Set RPN CURSOR to ON.
ITEM: RPN CURSOR → ON
3.
Check whether there are any compensated pixels close to the pixel to be compensated with the CURSOR JUMP
function.
Tip
Correction points can be checked effectively by placing the cursor in advance close to the pixel to be compensated
by using CURSOR H POS. and CURSOR V POS..
• When the target pixel is above the cursor position,
ITEM: CURSOR JUMP → PREV
• When the target pixel is under the cursor position,
ITEM: CURSOR JUMP → NEXT
HSC300RF/HSC100RF/HSC300R/HSC100R