Adjustment Procedure
1.
Open the SERVICE menu, and adjust the item so that the specification is satisfied.
MENU: SERVICE
PAGE: OHB_ADJ2
ITEM:
• V-SUB [R], [G], [B]
• TEST MODE: ON
Specification:
Format
1080/59.94i (50i)
1080/59.94P (50P)
1080/59.97PsF (25PsF)
2.
Execute file storing.
MENU: SERVICE
PAGE: OHB_ADJ2
ITEM: STORE FILE
3.
Set the setting of MSU-1000 or the menu of this unit.
• Setting for MSU-1000
ON button (shutter control block) → ON (lit)
SHUTTER SPEED → 1/500
• Setting for this unit
MENU: SERVICE
PAGE: OHB_ADJ2
ITEM: SHUTTER: ON
ITEM: SHUT_SPEED: 1/500
4.
Input the same value as the value adjusted according to step 1, and execute file storing.
MENU: SERVICE
PAGE: OHB_ADJ2
ITEM: STORE FILE
5.
Make the following settings if the MSU-1000 is used.
ON button (shutter control block) → OFF (dark)
6.
Set the value to the value adjusted in step 1, and do steps 2 to 5.
7.
Return the TEST MODE setting to OFF if this unit is used.
3-3-5.
Black Shading Adjustment
Preparation
• Setting for MSU-1000
CLOSE button → ON (lit)
GAMMA OFF button → OFF (lit)
MASTER GAIN → 12
MASTER BLACK → 30
HSC300RF/HSC100RF/HSC300R/HSC100R
R
G
450 mV
450 mV
435 mV
450 mV
415 mV
400 mV
B
370 mV
220 mV
185 mV
3-12