4.
When the cursor stopped at a position near the target pixel:
1)
Delete the data because the data is recorded so as to compensate the pixel at the cursor position.
ITEM: DELETE RPN → EXEC
2)
A message "DELETE DATA OK? YES → NO" appears. Select YES with the rotary encoder and then press
the rotary encoder.
Note
Appearance of an RPN next to the pixel to be compensated means that adjacent RPNs exit. If an RPN appears
in the diagonal direction, the RPN cannot be compensated. In this case, the CCD or the CCD block must be
replaced. For more information, contact your local Sony Sales Office/Service Center.
3)
If nothing has changed, change the compensation position.
Move the cursor horizontally or vertically to check whether the RPN can be compensated.
4)
When the RPN has been successfully compensated, record the data.
ITEM: RECORD RPN → EXEC
5)
A message "RECORD DATA OK? YES → NO" appears. Select YES with the rotary encoder and then press
the rotary encoder.
6)
A message "COMPLETE!" appears and the data is recorded.
Note
When two RPNs are vertically adjacent to each other, record the data at the position where one RPN can be
compensated.
Then shift the cursor vertically by 1 at the same horizontal address and check whether the other RPN can
becompensated.
When the other RPN has been successfully compensated, record the data of the RPN.
When two RPNs are horizontally adjacent to each other, move the cursor to the position where the left RPN
can be compensated. Next, set RPN WIDTH to 2 and record the data, and then check whether these RPNs can
be successfully compensated.
If the RPN compensation failed, delete the data.
Increase RPN WIDTH to 3, 4, ..., and select a value that allows the best compensation.
For an RPN that has a horizontal extent (smear), increase RPN WIDTH from 1 to 2, 3, 4, ..., and select a value
that allows the best compensation.
3-6-4.

Performing Automatic RPN Detection Effectively

Preparation
• Lens iris→ CLOSE
• Setting for MSU-1000
BARS button → OFF (dark)
SHUTTER button → OFF (dark)
HSC300RF/HSC100RF/HSC300R/HSC100R