Sony Power HAD FX HSC300R Service Manual page 100

Hd color camera
Table of Contents

Advertisement

• Lens iris: A = 600 ±20 mV (F4 to F5.6)
If the lens aperture is greater than F5.6, adjust the light amount with the shutter.
A
• Lens focus: ∞
• Lens extender/shrinker: ×2, ×0.8 → OFF
• Set the camera setup menu as follows.
MENU: OPERATION
PAGE: LENS FILE
ITEM: FILE
Select the file in accordance with the lens attached. If there is no appropriate file, select NO OFFSET, then change
the name of lens with MSU.
Adjustment Procedure
1.
Operate the control panel of MSU-1000, and perform the automatic white balance adjustment.
WHITE button → ON (lit)
2.
If the shading is monitored, adjust it with menu control of MSU-1000.
1)
MAINTENANCE button → ON (lit)
2)
Touch panel operation: [Camera] → [White Shading] → [R]
3.
Adjust this so that the R channel becomes as flat as possible.
(Check this in the mode of V: FIELD, H: LINE.)
H: LINE
(H SAW)
V: FIELD
(V SAW)
4.
Make the same adjustment for channels G and B.
5.
Operate the control panel of MSU-1000, and perform the automatic white balance adjustment.
WHITE button → ON (lit)
HSC300RF/HSC100RF/HSC300R/HSC100R
(H PARA)
(V PARA)
3-14