GTH Transceiver Clock Connections
See
Figure 1-2
clock inputs. Connect these cables to the SuperClock-2 module as follows:
CLK0_P coax cable → SMA connector J7 (CLKOUT1_P) on the SuperClock-2 module
CLK0_N coax cable → SMA connector J8 (CLKOUT1_N) on the SuperClock-2 module
Any one of the five differential outputs from the SuperClock-2 module can be used to source
Note:
the GTH reference clock. CLKOUT1_P and CLKOUT1_N are used here as an example.
MGT TX/RX Loopback Connections
See
Figure 1-2
(RX0, RX1, RX2, and RX3) and the four transmitters (TX0, TX1, TX2, and TX3). Use eight SMA
female-to-female (F-F) adapters
shown in
Figure
TX0_P → SMA F-F Adapter → RX0_P
TX0_N → SMA F-F Adapter → RX0_N
TX1_P → SMA F-F Adapter → RX1_P
TX1_N → SMA F-F Adapter → RX1_N
TX2_P → SMA F-F Adapter → RX2_P
TX2_N → SMA F-F Adapter → RX2_N
TX3_P → SMA F-F Adapter → RX3_P
TX3_N → SMA F-F Adapter → RX3_N
To ensure good connectivity, it is recommended that the adapters be secured with a wrench;
Note:
however, do not over-tighten the SMAs.
X-Ref Target - Figure 1-6
VCU1287 IBERT Getting Started Guide
UG1203 (v2016.4) December 15. 2016
to identify the P and N coax cables that are connected to the CLK0 reference
to identify the P and N coax cables that are connected to the four receivers
(Figure
1-7:
Figure 1-6: SMA F-F Adapter
www.xilinx.com
Chapter 1: VCU1287 IBERT Getting Started Guide
1-6) to connect the transmit and receive cables as
X15545-121416