Kubota WSM J Series Workshop Manual page 10

Diesel generator
Table of Contents

Advertisement

J SERIES, WSM
[60Hz]
Model
Type
Insulation
class
Frequency
Standby
output
Prime output
Voltage
110 / 220V
Rated
amperage
Number of
phases
Number of
poles
Power factor
Model
Design
Number of
cylinders
Bore x Stroke
Displacement
Combustion
system
Compression
ratio
Cooling
system
Lubricating
system
Lubricating oil
Starting
system
Stop solenoid
Battery
Fuel tank
capacity
Cooling
system
(2.4U.S.qts.,2.0 Imp.qts.)
capacity
Crankcase oil
capacity
(2.3U.S.qts.,2.0 Imp.qts.)
Continuous operating
hours (at 3/4 load)
Net weight
Emergency stop
During engine operation, automatic shutdown will
mechanism
occur when either the oil pressure or the water
temperature is abnormal.
With Caster
J107
-STD
-SA
-STD
Revolving-field, brush type, separate and self - excitation system, AC generator
7.1 kVA (7.1 kW)
11.0 kVA (11.0 kW)
6.5 kVA (6.5 kW)
127 / 220V
110 / 220V
59.1 /
51.2 /
90.9 /
29.5A
29.5A
45.5A
Z482-B-SEC
2
67 x 68 mm (2.52 x 2.68 in.)
3
479 cm
(29.23 cu.in.)
719 cm
23:1
Pressurized radiator, forced circulation with water pump
Energized to stop
38B20R
37 L
(9.8U.S.gals., 8.1 Imp.gals.)
2.3 L
(3.2U.S.qts.,2.6 Imp.qts.)
2.2 L
(3.6U.S.qts.,3.0 Imp,qts.)
15.5 Hr
225 kg (496 lbs)
255 kg (562 lbs)
Option
J110
-SA
-STD
Rotor coil: F Stator coil: B
60 Hz
15.4 kVA (15.4 kW)
10 kVA (10 kW)
14 kVA
(14 kW)
127 / 220V
110 / 220V
78.7 /
63.6 x 2 /
45.5A
63.6 A
Single
2
100 %
D722-B-SEC
D1005-BG-SEC
Vertical, liquid cooled, 4 cycle, diesel engine
3
3
(43.89 cu.in.)
1001 cm
Spherical combustion chamber
Forced lubrication by trochoid pump
Higher than CD class (API)
Electric type
55B24R
3.0 L
(3.5U.S.qts.,2.9 Imp.qts.)
3.4 L
(4.6U.S.qts.,3.8 Imp.qts.)
10.5 Hr
340 kg (750 lbs)
During engine operation, automatic shutdown will
occur when either the oil pressure or the water
temperature is abnormal or when the fan belt breaks.
7
SPECIFICATIONS
J114
J119
-SA
-STD
20.6 kVA (20.6 kW)
11.5 kVA
18.8 kVA
(11.5 kW) /
(18.8 kW)
14 kVA
(14 kW)
127 / 220V
110 / 220V
90.6 /
85.5 x 2 /
63.6A
85.5 A
V1305-BG-SEC
4
76 x 73.6 mm (2.99 x 2.90 in.)
3
3
(61.08 cu.in.)
1335 cm
(81.46 cu.in.)
22:1
Energized to run
80D26R (S)
79 L
(20.9U.S.gals.,17.4 Imp.gals.)
3.3 L
3.5 L
(3.7U.S.qts.,3.1 Imp.qts.)
4.3 L
5.7 L
(6.0U.S.qts.,5.0 Imp.qts.)
16.0 Hr
13.0 Hr
380 kg (838 lbs)
None
KiSC issued 10, 2016 A
-SA
11.5 kVA
(11.5 kW) /
18.8 kVA
(18.8 kW)
127 / 220V
90.6 /
85.5A
W10439640

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents