Settings For Sensor Adapter; How To Set The Equipment Id - Furuno FMD-3100 Instruction Manual

Ecdis setting and adjustments for pcu-3010
Hide thumbs Also See for FMD-3100:
Table of Contents

Advertisement

2.
SETTINGS FOR SENSOR
ADAPTER
The default Equipment ID of the Sensor Adapter is "MCV016". Set the individual
Equipment ID before connecting to the network.
Connect the Sensor Adapter to the ECDIS unit after setting the Equipment ID. Then
enter the other settings of the Sensor Adapter from the [Common Installation Setting]
menu on the ECDIS unit.
2.1

How to Set the Equipment ID

1. Set the IP address and subnet mask of the PC as shown below.
IP address: 172.31.16.200
Subnet mask: 255.255.0.0
2. Connect the laptop PC to the Sensor Adapter with the LAN cable.
3. Activate the web browser on the PC and enter the default IP address of the sensor
adapter: "172.31.17.108".
4. Access the [Common Installation Setting] menu and click [Basic Setting] on the
tab bar.
5. Select the Equipment ID from the drop-down list. The [Equipment Name],
[Equipment Type No.] and [IP Address] are automatically entered according to the
Equipment ID.
Setting range: "MCV001" to "MCV016"
6. After entering the setting, click [Save] on the Info bar. Several confirmation mes-
sages appear. Click [OK] to reboot the system.
If you want to discard the entry, click [Discard Changes].
How to restore the default Equipment ID
When you can not define the Equipment ID of the Sensor Adapter, restore the default
and set the Equipment ID again.
1. Turn on the No. 8 segment of the DIP switch S10 on the board in the MC-3000S.
2. Turn on the Sensor Adapter.
The Equipment ID of the Sensor Adapter turns to default "MCV016", and the IP
address is set to "172.31.17.108".
3. See section 2.1 for how to set the Equipment ID of the Sensor Adapter.
4. Turn off the No. 8 segment of the DIP switch S10 on the board in the MC-3000S.
MCV016
No.16 Sensor Adapter
MC-3000S
31
17
108
2-1