Furuno FMD-3100 Instruction Manual page 27

Ecdis setting and adjustments for pcu-3010
Hide thumbs Also See for FMD-3100:
Table of Contents

Advertisement

2. Check the check box of [MCV001] to activate.
3. Click [Details] to display the window as shown below. For the descriptions of the
each items, see step 3 of section 1.4.2.
4. Click [No.1 Sensor Adapter] on the menu bar.
The sensor adapter consists of four sub units: [Serial Input/Output], [Digital In-
put]*, [Digital Output]*, and [Analog Input]*. [Analog Input] is not used on the FMD-
3100.
* Not displayed when the MC-3000S is connected directly to LAN. If it is necessary
to change the setting, connect the MC-3000S via the PCU-3010.
5. Click [Serial Input/Output]. There are eight ports in the Serial Input/Output. [Serial
01] to [Serial 04] can input/output at 38,400 bps for the AIS and Gyro.
Not used
Not used
Not used
The connector no. on the MC-3000S board and the corresponding serial port no.
are shown in the following table.
Connector No.
J4
J5
J6
J7
6. Set the items referring to step 6 of section 1.4.2.
1. INITIAL SETTINGS AND ADJUSTMENTS
Serial Port No.
Connector No.
Serial 01
Serial 02
Serial 03
Serial 04
Serial Port No.
Serial 05
J8
Serial 06
Serial 07
J9
Serial 08
1-21