Factory Test & Default] Menu - Furuno FMD-3100 Instruction Manual

Ecdis setting and adjustments for pcu-3010
Hide thumbs Also See for FMD-3100:
Table of Contents

Advertisement

1.13
[Factory Test & Default] Menu
The [Factory Test & Default] menu does the factory test to check operation and
restores the system default settings.
Factory Test
Click [Start] to perform the factory test. The result of the test is shown on the display.
If "NG" appears, confirm the state of the unit on the [System Monitor] menu.
Factory Default
The factory default function restores all factory defaults (except the settings on the
[Basic Setting] menu). In the default arrangement all ECDIS units powered in the net-
work are restored to default condition.
Note: Restoring the unit to factory default will not erase user chart data or route
data.
1. Click [Reset to Factory Default]. The following message appears on the screen.
2. Click [OK] to restore the system to the default setting.
The progress bar shows update progress. When the restoration is completed, the
system is automatically rebooted.
3. If connected to the gateway network, the link is shown on the display after
completing the system reboot.
Click the link on the display to access the [Common Installation Setting] menu.
If connected to the sensor network, enter the IP address of the sensor network
to access the [Common Installation Setting] menu after completing the system
reboot.
1. INITIAL SETTINGS AND ADJUSTMENTS
The result of the test is shown in this area.