1. INITIAL SETTINGS AND ADJUSTMENTS
[Title]: Enter the title of the component.
[SOG Longitudinal Speed]: Select the data source of the longitudinal SOG.
[STW Longitudinal Speed]: Select the data source of the longitudinal STW.
[Bow Transverse Speed]: Select the data source of the longitudinal speed at the
bow position.
[Stern Transverse Speed]: Select the data source of the longitudinal speed at the
stern position.
[True Wind Direction Source]: Select the source of true wind direction indicated as
the red triangle in the center of the component.
[Relative Wind Direction Source]: Select the source of relative wind direction indi-
cated as the red triangle in the center of the component.
[Speed Type Source]: Select the data source same as [Longitudinal Speed Source]
to show the abbreviated name of the data source unit.
[Sensor Name Source]: Select the appropriate sensor name source.
[Unit]: Set the unit of the ship's speed.
[Decimal Place]: Check the checkbox to show the value after decimal point
[Mathematical Sign]: Check the checkbox to show the minus sign (-) when the value
is minus.
[Mirror Vertically]: Check the checkbox to invert the display vertically.
• DP
For the setting, see the description for [Compass], [Horizontal Ruler], [Azimuth Pro-
motion], and [Doppler Log].