3-18. INFO BUTTON STATS

3-19. FILTER BUTTON
STATS
3-20. TEMP BUTTON
STATS
Sept. 2007
Recovery Information for each Vat
1. Press and release
the recovery time that oil temperature went from 250°F (121°C)
to 300°F (149°C) shows in the right display. For example,
REC
5:30
for the oil temperature to recover to 300°F (149°C) from 250°F
(121°C).
If no buttons are pressed within 5 seconds in any of stats modes, the
controls revert back to normal operation.
Cook Cycles Remaining before Filtering
1. Press and release either
"COOKS REMAINING" and the right display shows the
������������������������
REMA INING
cook cycles on the left vat, the controls asks the operator if they are
���������������������������������
vat.
Time and Date
2. Press either
or
in the displays.
Actual Oil Temperature
1. Press
and the actual oil temperature shows in the display, for
each vat.
Set-point Temperature
2. Press
twice and SP shows in the display, along with the set-
point (preset) temperature of each vat.
3-22
Model LVE-102, 103, 104
and REC shows in the left display and
means it took 5 minutes and 30 seconds
or
and the left display shows
3
6
means after 3 more
twice and the time-of-day and date shows
. For example,