2-8. ELECTRICAL
REQUIREMENTS
Aug. 2007
Check the data plate, mounted on the inside of the left door, to
determine the correct power supply.
This fryer must be adequately and safely grounded
(earthed) or electrical shock could result. Refer to
local electrical codes for correct grounding (earthing)
procedures or in absence of local codes, with The National
Electrical Code, ANSI/NFPA No. 70-(the current edition).
In Canada, all electrical connections are to be made in
accordance with CSA C22.1, Canadian Electrical Code
Part 1, and/or local codes.
To avoid electrical shock, this appliance must be equipped
with an external circuit breaker which will disconnect all
ungrounded (unearthed) conductors. The main power
switch on this appliance does not disconnect all line
conductors.
(FOR EQUIPMENT WITH CE MARK ONLY!)
To prevent electric shock hazard this appliance must be
bonded to other appliances or touchable metal surfaces
in close proximity to this appliance with an equipotential
bonding conductor. This appliance is equipped with an
equipotential lug for this purpose. The equipotential lug is
marked with the following symbol