3-15. DISCARDING OIL
FROM VAT USING
OIL DISCARD
SHUTTLE
Figure 1
Figure 2
Closed
Figure 3
Aug. 2009
NOTE: ENSURE DISPOSE IS SET TO NO OR VAC
1. Open center door and pull the drain pan assembly from under fryer
and replace with oil discard shuttle. Figures 1 & 2.
2. Press and hold
MENU*", along with "1.AUTO FILTER?".
3. Press and release
"3.DISPOSE". Press
"YES NO". (If control suspects oil in drain pan "CAUTION IS
THERE OIL IN PAN? YES NO" may show in display. Make sure
drain pan is empty before proceeding )
4. Press
PLACE? "YES NO".
5. With discard shuttle rolled into place, press
shows "DRAINING". Oil now drains from the vat into the shuttle.
Fish vat drain valves must be manually opened. Open the door and
turn the drain handle from the horizontal position to the vertical
position and the oil drains from the vat. Figure 3
6. Display shows "VAT EMTY "YES NO". Verify that vat is empty,
and press
Open
7. Display shows "CLN VAT COMPLETE" "YES NO". Once vat is
clean, press
8. Display shows "MANUAL FILL POT", followed by "IS VAT
FILLED" "YES NO". Fill the vat to the lower indicator line on the
rear of the vat and then press
Oil (locations without RTI) instructions from Section 3-2.
Controls return to normal operation.
9. Remove the discard shuttle from under fryer and replace with the
���������
(on either side) until display shows "*FILTER
button twice until display shows
ü
button and display shows "DRAINING?"
ü
button and display shows "IS DISPOSAL UNIT IN
ü
button.
ü
����������������������
ü
.
3-18
Model LVE-102, 103, 104
ü
button and display
button. (See Filling or Adding

Advertisement