Gun Setup; Gun Setup Procedure; Hvlp Gun Setup Procedure - Graco Pro Xp 60 WB Instructions Manual

Hide thumbs Also See for Pro Xp 60 WB:
Table of Contents

Advertisement

Gun Setup

Gun Setup
Setup
Gun
Gun
Setup
Gun Setup
Setup Procedure
Procedure
Gun
Gun
Setup
Procedure
To reduce the risk of fire and explosion, fluids used
must meet the following flammability requirements:
• FM,
FM,
FM, FMc
FMc Approved:
FMc
Approved:
Approved:
Material does not sustain burning in accordance
with the Standard Test Method for Sustained
Burning of Liquid Mixtures, ASTM D4206.
• CE
CE
CE- - - EN
EN 50059
EN
50059 Compliant:
50059
Compliant:
Compliant:
Material is classified as non-ignitable as defined
by EN 50059: 2018.
For more information, see
Ignitability of Coating Materials, page
Contact with the charged components of the spray
gun will cause an electric shock. Do not touch the
gun nozzle or electrode or come within 4 in. (102
mm) of the front of the gun during operation or
until performing the
Fluid Voltage Discharge and
Grounding Procedure, page
Follow the
Fluid Voltage Discharge and Grounding
Procedure, page 33
when you stop spraying and
whenever you are instructed to discharge the
voltage.
To reduce the risk of component rupture, which
can cause serious injury, do not exceed the
maximum working pressure of the lowest rated
system component. This equipment has a 100 psi
(0.7 MPa, 7 bar) maximum working air and fluid
pressure.
To reduce the risk of an injury, follow the
Pressure Relief Procedure, page 33
are instructed to relieve the pressure.
20
92.
33.
whenever you
For additional steps to set up specialty guns,
see
Soft Spray Gun Setup Procedure, page
Round Spray Gun Setup Procedure, page
HVLP Gun Setup Procedure, page
Abrasive Material Gun Setup Procedure, page
and
Mold Release Gun Setup Procedure, page
See the following figure to locate the electrostatic
gun controls.
Figure 13 Electrostatic Gun Controls
1. Check that the retaining ring (6) is tight, securing
the fluid nozzle (4) and air cap (5).
Note
The gun is shipped with the fluid nozzle
and air cap installed. To select a
different size fluid nozzle or air cap, see
Fluid Nozzle Selection Chart, page
and
Air Cap Selection Guide, page
To install the nozzle and air cap, see
Cap and Nozzle Replacement, page
2. Turn OFF (O) the ES On-Off switch (J).
24,
26,
25,
28,
30.
77,
80.
Air
49.
3A7504A

Advertisement

Table of Contents
loading

This manual is also suitable for:

3a7504aGo industrial pro xp 60 wb gunPro xp 60 wb mrgL60t18L60m18L60m19

Table of Contents